Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle

نویسندگان

  • H Shah
  • V Chavali
  • R Daveshwar
چکیده

OBJECTIVE The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis. MATERIALS AND METHOD Eight school going children in the age group of 11-16 years with volar Barton fractures were treated with a volar plate using the buttress principle without inserting screws in the distal fragment. Patients were evaluated over a period of 18 months. Clinical evaluation was done using the Green O'Brien criteria and radiological evaluation using the Sarmiento criteria. RESULTS The average union time was two months. All the patients had good to excellent functional outcome with full extension and flexion. CONCLUSION Buttress plating of volar Barton fractures in the adolescent age group is an excellent technique to achieve satisfactory outcome without violation of the physis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures

Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...

متن کامل

Extensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius--a case report.

Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to i...

متن کامل

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...

متن کامل

Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial

BACKGROUND Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currentl...

متن کامل

Treatment of volar Barton's fractures: comparison between two common surgical techniques.

BACKGROUND Volar Barton's fractures are not uncommon but more convincing treatment methods are still controversial. Currently, open reduction with buttress plating or closed reduction with external fixation and percutaneous Kirschner wire fixation have achieved most support. METHODS Twenty-three consecutive volar Barton's fractures treated with either open reduction and buttress plate fixatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015