Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.
نویسندگان
چکیده
INTRODUCTION The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne. METHODS Cyclic fatigue test with a simultaneous pecking motion was performed with the instrument (n = 10 each) operating in the recommended reciprocation motion until fracture for the Reciproc R25 and WaveOne Primary files. ProTaper F2 was tested in continuous rotation to serve as a control for comparison. The number of cycles to fracture (NCF) was determined by measuring the time to fracture. The length of the fragment was measured and the fracture surface was examined by using scanning electron microscopy. Torsional strength was measured by using a torsiometer after fixing the apical 5 mm of the instrument rigidly. Statistical analysis was performed by using one-way analysis of variance. RESULTS The results showed that Reciproc had a higher NCF and WaveOne had a higher torsional resistance than the others. Both reciprocating files demonstrated significantly higher cyclic fatigue and torsional resistances than ProTaper (P < .05). The fractographic analysis showed typical features of cyclic fatigue and torsional failure for all instruments. CONCLUSIONS The 2 brands of NiTi file for use with a reciprocation motion seem to have superior mechanical properties.
منابع مشابه
Cyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus
The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...
متن کاملDifferences in cyclic fatigue resistance at apical and coronal levels of Reciproc and WaveOne new files.
INTRODUCTION Recent improvements in alloys, kinematics, and concepts have been combined to increase the cyclic fatigue resistance of nickel-titanium (NiTi) instruments. The aim of this study was to compare the cyclic fatigue resistance of new M-Wire reciprocating WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and Reciproc (VDW GmbH, Munich, Germany) files at 2 levels. METHODS Sixty Rec...
متن کاملTF TM Adaptive : a novel approach to nickel - titanium instrumentation
instruments have been traditionally used with a continuous rotary motion, but more recently, a new approach to the use of nickel-titanium instruments in a reciprocating movement has been introduced by Yared (2004). The clockwise (CW) and counter-clockwise (CCW) rotations used by Yared were four-tenths and two-tenths of a circle respectively, and the rotational speed utilized was 400 rpm. The co...
متن کاملInfluence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments.
INTRODUCTION The aim of this study was to evaluate the resistance to flexural fatigue of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (VDW, Munich, Germany), Mtwo (Sweden & Martina, Padova, Italy), and Twisted File (TF; SybronEndo, Orange, CA) instruments used in continuous rotation or in 2 different reciprocating motions. METHODS A total of 180 nickel-titanium files from 4 brands mar...
متن کاملIs the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?
AIM To compare cyclic fatigue resistance of two geometrically similar nickel-titanium instruments, used in conditions similar to clinical use in reciprocating and continuous rotary motion. METHODOLOGY Four groups of eighteen instruments each, Reciproc(®) files sizes ISO 25 and 40 (R25 and R40) and Mtwo(®) files sizes ISO 25 and 40 (M25 and M40), were tested in reciprocating and continuous rot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 38 4 شماره
صفحات -
تاریخ انتشار 2012