Walking and Stair Descent Following Minimally Invasive Total Knee Arthroplasty
نویسندگان
چکیده
Introduction: Total knee arthroplasty (TKA) is a surgery commonly used to relieve the pain caused by osteoarthritis at the knee joint. Previous studies have shown patients with degenerative joint disease walk more slowly than normal subjects due to decreases in stride length and cadence (Stauffer et al. 1977). Falls on stairs are a leading cause of injury in older adults (Starzell, et al., 2000). Studies have shown that stair descent moments at the knee are three times moments measured during level walking (Andriacchi, et al., 1980). Knee flexion angles required to successfully descend stairs are greater than the angles necessary for level walking. The higher demands placed on the knee joint during stair descent can limit the ability of patients with joint deficiencies from performing this activity.TKA is used to restore range of motion to the knee joint and reduce pain. Minimally invasive surgery produces less disruption to the soft tissues surrounding the knee joint providing the potential for recovery of ambulatory ability over a short period of time. The authors of this study hypothesized that the walking and stair descending ability of patients four months after total knee arthroplasty performed using computer navigation and minimally invasive techniques would not be different to the control group. Materials and Methods: Eighteen TKA patients (8 males, 10 females; 73 ± 8.1 years) volunteered to participate in the walking study and eleven of these subjects (5 males, 6 females; 73 ± 7.8 years) participated in the stair descent trials. Data were also collected from fifteen healthy agematched volunteers from the same community (5 males, 10 females; 69 ± 6.2 years). Motion analysis data were collected using a ten camera motion capture system (Motion Analysis Corp., Santa Rosa, CA) with lower body limb segments defined by reflective markers. Subjects were asked to walk at a self selected speed along an eight meter walkway embedded with four force platforms (AMTI, Watertown, MA) and negotiate a stair system consisting of three steps mounted on two of the force platforms. Forces were recorded for all three steps of the stair system. A minimum of five trials were recorded for each subject. Mean values for each of the selected kinematic and kinetic variables were compared using paired ttests (α = 0.05) to compare preand post-surgery values and unpaired ttests to compare post surgery values with controls. Results: Analysis of the results from walking trials showed a significant improvement in cadence (97.6 ± 13.8steps/min vs. 104.7 ± 10.3steps/min, p = 0.002) and velocity following surgery as well as an improvement in maximum knee flexion during swing and maximum vertical ground reaction force. Data for the post-surgery patients and the control group showed the patients had a significantly lower velocity (97.7 ± 15.9cm/sec vs. 106.8 ± 11.7cm/sec, p = 0.039) along with lower maximum knee flexion both in stance and swing and less knee flexion at toe off when walking (Figure 1). The peak in knee power absorption during stair descent occurs immediately prior to contralateral foot strike when the stance limb is supporting the full weight of the body while in a flexed position. Figure 2 shows power absorbed by the knee joint during stair descent for a normalized gait cycle. Peak knee power absorbed following surgery was significantly less than for controls (2.4 ± 0.4Nm/kg vs. 2.9 ± 0.6Nm/kg, p = 0.012). Cadence improved significantly following surgery but was still significantly different to the control group for both walking and stair descent. Significant variations in knee angle are not possible when descending stairs due to the need to position the foot within a defined area on each step. The changes in sagittal plane kinematics following surgery were not significant. There were significant differences between the knee power absorption measured for patients prior to surgery and the control group. Discussion: The results show that while there is an improvement in the patients walking ability following surgery, differences still exist between persons who have received TKA and age-matched controls. Patients walk faster following surgery indicating more confidence while the higher ground reaction force suggests less knee pain. Patients following surgery have a high variability in step length while walking possibly due to different rates of recovery. Stair descent is more challenging for older persons and provides an opportunity to measure differences not seen while performing other less demanding tasks. Understanding the limitations TKA causes in patients may help in the rehabilitation of these persons enabling them to become more independent sooner after surgery. The results indicate that while the patients have improved mobility they do not exhibit the same levels as control subjects. Further study is necessary to determine if more time is needed for knee kinematic and kinetic parameters to reach levels similar to those measured in healthy subjects. References: Andriacchi, T.P. et al. (1980). J. Bone & Joint Surg. 62-A, 749-757. Startzell, J.K., et al. (2000). J. Am. Geriatrics Society 48, 567-580. Stauffer, R.N., et al. (1977). Biomechanical gait analysis of the diseased knee joint. Clin Orthop Relat Res 126, 246-255
منابع مشابه
Stair dimension affects knee kinematics and kinetics in patients with good outcome after TKA similarly as in healthy subjects.
Joint biomechanics during stair walking may contain important information on functional deficits in patients with orthopaedic conditions but depend on the stair dimension. The goal of this study was to compare knee kinematics and kinetics between patients with good outcome 2 years after total knee arthroplasty (TKA) and age-matched controls during stair ascent and descent at two different stair...
متن کاملA moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent
Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allow...
متن کاملMedial knee joint loading during stair ambulation and walking while carrying loads.
Carrying loads while walking or using stairs is a common activity of daily living. Knee osteoarthritis is associated with increased external knee adduction moment (KAM) during walking, so understanding how the additional challenges of stairs and carrying loads impact these moments is of value. Sixteen healthy individuals performed three types of MOTION (walking, stair ascent, stair descent) und...
متن کاملKnee Flexion and Daily Activities in Patients following Total Knee Replacement: A Comparison with ISO Standard 14243
Walking is only one of many daily activities performed by patients following total knee replacement (TKR). The purpose of this study was to examine the hypotheses (a) that subject activity characteristics are correlated with knee flexion range of motion (ROM) and (b) that there is a significant difference between the subject's flexion/extension excursion throughout the day and the ISO specified...
متن کاملLoading of the Lower Extremity and Low Back When Using Wedge Orthotics during Walking and Stair Negotiation
Wedge orthotics are commonly prescribed for patients with hyperpronation and/or low back pain to improve lower limb alignment and to reduce pain. The purpose of this study was to examine the kinetic effects of medial and lateral wedge orthotics during walking and stair negotiation. Twenty-two healthy young adults participated in the study. Each participant wore no wedge (W0) as a baseline and l...