Single-tube method for nucleic acid extraction, amplification, purification, and sequencing.

نویسندگان

  • Rebecca L Margraf
  • Sam Page
  • Maria Erali
  • Carl T Wittwer
چکیده

BACKGROUND The hepatitis C virus (HCV) genotype determines patient prognosis and duration of treatment, but sequencing of the gene is lengthy and labor-intensive. We used a commercially available nucleic acid extraction system to develop a single-tube extraction-to-sequencing (STETS) method for HCV genotyping. METHODS HCV RNA was purified and amplified in tubes coated with a solid-phase matrix that irreversibly bound nucleic acid during the extraction step. After reverse transcription-PCR, the amplicon was adsorbed to the original extraction matrix for purification and use in the subsequent sequencing reactions. RESULTS The STETS method generated genotyping-quality sequence for a range of HCV titers from 500 to 6,000,000 IU/mL. If a viral sample was detected during real-time reverse transcription-PCR, it could be sequenced and genotyped. Read lengths >600 bases were observed with the STETS method. Mixed infections were detected and genotyped if at least 15% of the minor species was present. Combining the STETS method with consecutive sequencing provided a means of performing both forward and reverse sequencing in a single tube. CONCLUSIONS A single-tube nucleic acid extraction-to-sequencing method, which requires less time and labor than conventional methods, generates HCV sequence data that are equivalent to conventional methods and can be used to genotype HCV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sample Preparation for Point of Care Molecular Diagnostics of STIs

Brunel DoCLab is part of the esti 2 consortium developing electronic self-testing instruments for sexually transmitted infections using nucleic acid amplification testing (NAAT). A proprietary sample collection device has been designed to integrate directly with a microfluidic cartridge. Cell lysis was conducted using a chemical method and nucleic acid purification was done on an activated cell...

متن کامل

Nucleic acid purification from plants, animals and microbes in under 30 seconds

Nucleic acid amplification is a powerful molecular biology tool, although its use outside the modern laboratory environment is limited due to the relatively cumbersome methods required to extract nucleic acids from biological samples. To address this issue, we investigated a variety of materials for their suitability for nucleic acid capture and purification. We report here that untreated cellu...

متن کامل

Sensitivity and Specificity of Nucleic Acid Sequence-Based Amplification Method for Diagnosis of Cutaneous Leishmaniasis

Abstract Background and Objective: Culture, microscopic method is a gold standard method for identification of Lishmania parasite. The use of Molecular methods such as RT- PCR compared to microscopic methods has a higher sensitivity and specificity however, it is not widely used due to its expensive equipment and the time requested. The use of nucleic acid sequence based amplification (NASBA) ...

متن کامل

Rapid, single-tube method for quantitative preparation and analysis of RNA and DNA in samples as small as one cell

BACKGROUND Current methods for accurate quantification of nucleic acids typically begin with a template preparation step in which DNA and/or RNA are freed of bound proteins and are then purified. Isolation of RNA is particularly challenging because this molecule is sensitive to elevated temperatures and is degraded by RNases, which therefore have to be immediately inactivated upon cell lysis. M...

متن کامل

Nucleic acid sample preparation using spontaneous biphasic plug flow.

Nucleic acid (NA) extraction and purification has become a common technique in both research and clinical laboratories. Current methods require repetitive wash steps with a pipet that are laborious and time-consuming, making the procedure inefficient for clinical settings. We present here a simple technique that relies on spontaneous biphasic plug flow inside a capillary to achieve sample prepa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 10  شماره 

صفحات  -

تاریخ انتشار 2004