Clear evidence of fluorescence resonance energy transfer in gas-phase ions.
نویسندگان
چکیده
Fluorescence resonance energy transfer (FRET) is a distance-sensitive method that correlates changes in fluorescence intensity with conformational changes, for example, of biomolecules in the cellular environment. Applied to the gas phase in combination with Fourier transform ion cyclotron resonance mass spectrometry, it opens up possibilities to define structural/conformational properties of molecular ions, in the absence of solvent, and without the need for purification of the sample. For successfully observing FRET in the gas phase it is important to find suitable fluorophores. In this study several fluorescent dyes were examined, and the correlation between solution-phase and gas-phase fluorescence data were studied. For the first time, FRET in the gas phase is demonstrated unambiguously.
منابع مشابه
Investigating the resonance energy and charge transfer in the clonidine and c60-clonidine-fullerene carriers with quantum chemistry calculations
Clonidine has two aromatic rings in which halogens are attached to one ring in this study, both in drug state and in fullerene nanostructure, and by changing the type of halogen at the * HF / 6-31G level and in The gas phase was first optimized and then the NBO calculations were performed. The results obtained in N61, N63 and N5, N3 indicate the highest rhizanese energy and load transfer that, ...
متن کاملPulsed fluorescence measurements of trapped molecular ions with zero background detection.
Sensitive methods have been developed to measure laser-induced fluorescence from trapped ions by reducing the detection of background scattering to zero levels during the laser excitation pulse. The laser beam diameter has been reduced to approximately 150 microm to eliminate scattering on trap apertures and the resulting laser-ion interaction is limited to a volume of approximately 10(-5) cm w...
متن کاملAction-FRET of a Gaseous Protein
Mass spectrometry is an extremely powerful technique for analysis of biological molecules, in particular proteins. One aspect that has been contentious is how much native solution-phase structure is preserved upon transposition to the gas phase by soft ionization methods such as electrospray ionization. To address this question-and thus further develop mass spectrometry as a tool for structural...
متن کاملIntermolecular approach to metal ion indicators based on polymer phase transitions coupled to fluorescence resonance energy transfer.
An approach to ratiometric fluorescence detection of quenching metal ions was devised by copolymerizing N-isopropylacrylamide with small percentages of bipyridine and amine monomers. The copolymer was divided into two portions. The amine group on one portion was functionalized with AlexaFluor555 (donor fluorophore) and the other with AlexaFluor647 (acceptor fluorophore). The indicator consists ...
متن کاملFRET measurements of trapped oligonucleotide duplexes
Sensitive methods developed to measure laser-induced fluorescence from trapped ions have been applied to study the intermediate states of the dissociation of oligonucleotide duplexes. Double-stranded oligonucleotide anions were prepared with FRET donor/acceptor pairs attached. Gas phase ions were generated by electrospray ionization and injected into a heated quadrupole ion trap where they were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society for Mass Spectrometry
دوره 16 9 شماره
صفحات -
تاریخ انتشار 2005