Analysis of multifrequency impedance of biologic active points using a dry electrode system.

نویسندگان

  • Min Soo Kim
  • Young-Chang Cho
  • Suk-Tae Seo
  • Chang-Sick Son
  • Yoon-Nyun Kim
چکیده

OBJECTIVES A system is being developed for measurement of biologic active points (BAPs) in humans using a modified dry electrode. The BAPs measuring system analyzed the electrical characteristics and searched for the position of BAPs using modified dry electrodes. SUBJECTS Skin electrical resistance at BAPs and non-BAPs was examined with a modified electrode system for healthy male subjects (ages 21-40). Four (4) acupuncture points of PC-4, PC-5, PC-6, and PC-7 on the left arms were chosen for BAPs. Bio-impedance was then conducted for BAPs and non-BAPS using a lock-in amplifier with a frequency range of 1 Hz-1 kHz. RESULTS Resistances of four BAPs were found to decrease to about 29%-59% of non-BAPs and reactance of BAPs was found to decrease to about 23%-41% of non-BAPs. The difference in electrical impedance between BAPs and non-BAPs was easily recognized since the average value of BAPs was measured at lower values than that of non-BAPs. Through these experiments, BAPs could be distinguished from non-BAPs based on electrical impedance. In addition, the electrical impedance model used-the electrical BAPs model-appears to be better suited for skin. CONCLUSIONS The proposed BAPs electrical model of skin can be adapted for interpretation of changes in the impedance characterization of skin. This system would be used for various skin diagnoses due to the simplicity and reliability of bio-impedance analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast EIT data acquisition system with active electrodes and its application to cardiac imaging.

A wide-band high-speed data acquisition system for electrical impedance tomography (EIT) is described. 32 active electrodes are used in the system, half of them as receive electrodes and the other half as drive electrodes. A buffer is mounted on the back of each receive electrode and a current source on each drive electrode. A multielectrode system with active electrodes was built to make it co...

متن کامل

A Reconfigurable Electrode Array for Use in Rotational Electrical Impedance Myography

This thesis describes the design of a novel handheld electrode probe and measurement system for use in rotational electrical impedance myography (EIM), which is a method for diagnosing neuromuscular disease. The probe can be controlled from a PC via USB and uses an array of small electrode cells that can be connected together into larger electrodes with the help of crosspoint switches. A measur...

متن کامل

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording

Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal. Recently introduced dry electrodes with rigid metal pins overcome most of these problems; however, their rigidity causes discomfort and pain. This paper presents dry electrodes offering high user comfort, since they are fabri...

متن کامل

P300 Brain-Computer Interface Performance: A dry electrode study

Most brain-computer interfaces (BCI) are based on one of three types of electroencephalogram (EEG) signals: P300s, steady-state visually evoked potentials (SSVEP), and event-related desynchronization (ERD). EEG is typically recorded non-invasively using active or passive electrodes mounted on the human scalp. The common setup requires conductive electrode gel to get the best entrance impedance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of alternative and complementary medicine

دوره 18 9  شماره 

صفحات  -

تاریخ انتشار 2012