Marker alignment for Guglielmi detachable coil embolization: practical considerations.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Aneurysm embolization is not without risk: numerous technical aspects are considered before, during, and after the procedure. The purpose of this study was to show the position of the detachment zone of a Guglielmi detachable coil (GDC) with respect to the catheter tip for various microcatheters and marker alignments. METHODS Six types of commonly used microcatheters were tested (Excel-14, Excelsior, FasTracker-10, Prowler-10, Prowler-14, and Rebar-14). First, the catheter markers and the distance from the catheter tip to the distal end of the proximal and distal markers of each catheter were compared. Second, the coil maker was aligned with the catheter marker. Third, the distal 3 cm of the microcatheter was modified by random shaping, with or without steaming. Last, marker alignment was tested with resterilized microcatheters (ethylene oxide gas sterilization). RESULTS The length of the catheter marker and the distance between the catheter tip and the distal end of the proximal and distal catheter markers varied among the microcatheters. Sometimes, they varied even within the same microcatheter type. When a GDC was advanced until the proximal end of the marker on the delivery wire was exactly distal to the proximal catheter marker, the coil detachment zone was positioned at approximately 1.0 to 1.5 mm outside the catheter tip. Steaming or shaping of the distal 3 cm of the microcatheters resulted in the GDCs protruding more from the catheter tip. Resterilization also had an effect of marker distance shortening. Microcatheters were easily stretched by usual handling, such as removing a shaping mandrel from the catheter tip. CONCLUSION Our study shows that proper marker alignment is influenced by many factors, including microcatheter type, steaming, shaping, sterilization, and manual handling.
منابع مشابه
Thrombosis in giant basilar tip aneurysms during coil embolization.
Two patients with giant basilar tip aneurysms underwent coil embolization, one with both platinum fiber and platinum Guglielmi detachable coils and the other with Guglielmi detachable coils only. In both cases, spontaneous intraaneurysmal thrombosis occurred outside the coil mass, presumably a result of disruption of the intraaneurysmal flow pattern.
متن کاملA technique of GDC embolization for deeply bilobulated aneurysms.
The endovascular occlusion of deeply bilobulated aneurysms is a technical challenge. Recently, we successfully treated three patients with deeply bilobulated aneurysms by using Guglielmi detachable coils. The embolization technique was conventional, but it required several special technical considerations. In this report, we describe the technique of coil embolization of deeply bilobulated aneu...
متن کاملAneurysm retreatment after Guglielmi detachable coil and nondetachable coil embolization: report of nine cases and review of the literature.
OBJECTIVE Guglielmi detachable coil embolization of cerebral aneurysms is becoming increasingly used to manage certain intracranial lesions based on aneurysm geometry, patient condition, and patient and surgeon preferences. Aneurysm recurrences or incomplete initial treatments are not uncommon, making repeat treatment necessary using either surgical or endovascular techniques. METHODS Between...
متن کاملExtracranial aneurysm and arteriovenous fistula: embolization with the Guglielmi detachable coil.
PURPOSE To evaluate the feasibility and safety of Guglielmi detachable coils for endovascular treatment of extracranial aneurysm and arteriovenous fistula. MATERIALS AND METHODS Embolization with Guglielmi detachable coils delivered through Tracker-18 microcatheters was performed in 16 patients. This patient group had eight renal artery aneurysms and 11 arteriovenous fistulas (three cases of ...
متن کاملGuglielmi detachable coil extraction: suction generated by pusher-wire withdrawal after coil detachment within an intracranial aneurysm.
We present a case of Guglielmi detachable coil extraction into a microcatheter after coil detachment during embolization of a superior hypophyseal artery aneurysm; extraction was a result of the suction generated during pusher-wire withdrawal. Experimental simulations using many coil and microcatheter combinations were used to identify factors that contribute to the likelihood of this phenomenon.