BACKGROUND The aim of this study is to explore the clinical outcomes of anatomical allograft or fibula shaft augmentation with locking compression plates (LCPs) in elderly patients with four-part proximal humeral fracture (PHF). METHODS A total of 22 elderly patients with four-part PHF underwent allograft augmentation with LCPs for treatment. Among them, 7 cases received anatomical allograft and 15 patients received fibula shaft. Constant-Murley score (CMS), the disability of the arm, shoulder and hand (DASH) score, and subjective ratings, radiographic imaging, range of motion (ROM), and complications were recorded as postoperative evaluations. RESULTS Although the ROM and strength were considerably limited compared with the normal side, there were no significant differences in pain and daily activity between the unaffected and affected sides at the last follow-up according to the CMS. Additionally, no significant differences were found in the subjective ratings and CMS and DASH scores between the patients augmented with fibular shaft and anatomical allograft. Among the 15 patients who received fibular shaft, one case developed avascular necrosis (AVN) and screw cutout, but satisfactory outcomes were obtained after removal of implant. Besides, varus displacement occurred in one case, the patient acquired good function without revision. There were no infection, bone nonunion, and hardware-related complications occurred in any case. CONCLUSIONS Both anatomical allograft and fibula shaft with LCPs showed relatively good clinical outcomes for elderly patients with four-part PHF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial

BACKGROUND The optimal surgical management of dislocated three- and four-part fractures of the proximal humerus in elderly patients remains unclear. Most used techniques are hemiarthroplasty and angle-stable locking compression plate osteosynthesis. In the current literature there is no evidence available presenting superior results between hemiarthroplasty and angle-stable locking compression ...

متن کامل

Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®

BACKGROUND Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elde...

متن کامل

Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly

Purpose The incidence of proximal humeral fractures is high in the elderly, and the superior management of these fractures remains a controversy. The study aims to compare clinical outcomes of intramedullary nails, locking plates and conservative treatment for the management of displaced proximal humeral fractures in the elderly. Patients and methods In this prospective study, a total of 198 ...

متن کامل

Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.

Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015