Different osteosyntheses for Colles' fracture

نویسندگان

  • Yngvar Krukhaug
  • Nils R Gjerdet
  • Odd J Lundberg
  • Peer K Lilleng
  • Leiv M Hove
چکیده

BACKGROUND AND PURPOSE In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different commercially available plates (3 volar and 2 dorsal) with standard K-wire fixation using a distal radial cadaver model. MATERIAL AND METHODS 42 human radial bones from 26 cadavers were included. The bone mineral density (BMD) was measured by DEXA in all bones, and the radial bones were assigned to 6 equiv alent groups based on bone density and total amount of mineral. A distal radial osteotomy was done and a dorsal 30-degree wedge of bone was removed. 1 K-wire fixation group and 5 plate groups were tested for rigidity, yield load, and maximum load. RESULTS When data from dorsally and volarly applied plates were pooled, we did not find any statistically significant differences between them regarding stiffness, yield load, and maximum load. The K-wire group showed significantly lower yield load than 3 of the plate groups. There were no statistically significant differences in yield load between the 5 plate groups. The K-wire group showed lower rigidity than the plate groups. The K-wire group and 1 plate group failed at a statistically significant lower maximum load than the 4 other plate groups. INTERPRETATION The volar plates had the same mechanical stability as the dorsally applied plates, and they are therefore a good alternative to dorsally applied plates. K-wire osteosynthesis was inferior to plate osteosyntheses regarding all mechanical properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a test system to analyze different hip fracture osteosyntheses under simulated walking.

The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of norm...

متن کامل

Biomechanical analysis of different osteosyntheses and the combination with bone substitute in tibial head depression fractures

BACKGROUND Tibial head depression fractures demand a high level of fracture stabilization to prevent a secondary loss of reduction after surgery. Elderly individuals are at an increased risk of developing these fractures, and biomechanical investigations of the fractures are rare. Therefore, the aim of this study was to systematically analyze different types of osteosyntheses in combination wit...

متن کامل

The Effects of Dorsal Cortical Comminution on Radiographic Results following Percutaneous Pinning for Extra-Articular Colles' Fracture

A number of studies have demonstrated that dorsal cortical comminution (DCC) can predict redisplacement after nonoperative treatment of Colles' fractures; however, the effects of a DCC defect on radiographic outcomes following percutaneous pinning for dorsally displaced extraarticular Colles' fractures are unclear. We, therefore, performed a retrospective study on 85 patients who sustained such...

متن کامل

The Effect of Fall-Related Factors on Colles’ Fracture

INTRODUCTION Distal forearm fracture is one of the most frequently observed osteoporotic fractures which may occur as a result of low energy falls such as falls from a standing height and may be linked to the osteoporotic nature of the bone especially in the elderly. In order to improve both the diagnosis of high fracture risk individuals and the fracture prevention methods, the influence of ex...

متن کامل

Aberdeen Colles' fracture brace as a treatment for Colles' fracture. A multicentre, prospective, randomised, controlled trial.

We carried out a randomised, prospective, multicentre clinical trial of the treatment of Colles' fractures. A total of 339 patients was placed into two groups, those with minimally displaced fractures not requiring manipulation (151 patients) and those with displaced fractures which needed manipulation (188 patients). Treatment was by either a conventional Colles' plaster cast (a control group)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2009