Ocular dimensions of the Chinese adolescents with keratoconus

نویسندگان

  • Weijun Jian
  • Yang Shen
  • Yingjun Chen
  • Mi Tian
  • Xingtao Zhou
چکیده

BACKGROUND Adolescent KC is a special segment of the general KC population because an adolescents's eyes are still susceptible to blurred vision and optical defocus during the sensitive period of ocular and visual development. In the present study, we evaluated the ocular dimensions of 53 KC adolescents. METHODS One hundred and six KC eyes of 53 (42 boys and 11 girls) KC adolescents (age 15.5 ± 1.7 years, range 11 to 18) were involved in this retrospective study. The eye with more severe KC (Severe Group) of each patient was compared with their less affected eye (Mild Group). Optical axial length (OAL) was measured by optical coherence biometry (IOL-master). Central corneal thickness, anterior chamber depth (ACD), flat keratometry value, steep keratometry value, and maximum keratometry value were assessed with an anterior segment analyzer (Pentacam HR). Anterior segment length (ASL) was manually measured from the 25 scheimpflug images captured by the Pentacam HR with the mean value recorded. The posterior segment length (PSL) was calculated with the formula "PSL = OAL-ASL". RESULTS The mean ACD, OAL, ASL, and PSL values of the Severe Group were 3.51 ± 0.32 mm, 24.76 ± 1.24 mm, 4.01 ± 0.30 mm and 20.76 ± 1.15 mm.While those of the Mild Group were 3.36 ± 0.29 mm, 24.97 ± 1.40 mm, 3.94 ± 0.35 mm and 21.03 ± 1.31 mm. The Severe Group has significantly higher ACD (t = 4.539, P < 0.001) value but lower OAL (t = - 3.120, P = 0.003) and PSL (t = - 4.537, P < 0.001) values when compared with those of the Mild Group. For the Severe Group, the Kmax values were significantly correlated with the SE values (R = - 0.385, P = 0.004), the ACD values (R = 0.375, P = 0.006), the ASL values (R = 0.308, P = 0.025) and the PSL values (R = - 0.317, P = 0.021), but not with the OAL values (R = - 0.220, P = 0.114). In the Mild Group, the Kmax values were negatively correlated with the SE (R = - 0.577, P < 0.001), OAL(R = - 0.533, P < 0.001), and PSL (R = - 0.523, P < 0.001) values, but not with ACD (R = - 0.110, P = 0.434) or ASL (R = - 0.182, P = 0.192) values. CONCLUSIONS For adolescent KC, the more keratoconic eyes may be characterized by deeper ACD but shorter OAL and PSL, when compared with the less affected ones.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

ویژگی‌های بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری

Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...

متن کامل

Prevalence and Associations of Steep Cornea/Keratoconus in Greater Beijing. The Beijing Eye Study

PURPOSE To evaluate the prevalence and associated factors of steep cornea/keratoconus in the adult Chinese population. METHODS The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range: 50-93 years). A detailed ophthalmic examination was performed including optical low-coherence reflectometry. Steep cornea/keratoconus were defined as an ant...

متن کامل

Identification of seven novel ZNF469 mutations in keratoconus patients in a Han Chinese population

PURPOSE To test for the potential presence of novel mutations in the zinc finger protein (ZNF469) gene in patients with sporadic keratoconus (KC) from a Han Chinese population. METHODS Fifty-three patients with primary KC, 30 patients with high myopia (HM), and 100 unrelated population-matched healthy controls without any ocular or systemic disorders, all of Han Chinese ethnicity, were recrui...

متن کامل

Fusion of Different Corneal Parameters to Improve the Diagnosis of Keratoconus

Purpose: To diagnose keratoconus from healthy eyes, as well as suspected keratoconus. Methods: Certain parameters were extracted from Casia, Corvis, and Pentacam HR devices for 3 groups of healthy, with keratoconus, and suspected keratoconus. This study was performed on 340 eyes with keratoconus, 310 normal eyes, and 350 suspected keratoconus. The processing method involved the fusion of featur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2018