Pathogen identification with laser-induced breakdown spectroscopy: the effect of bacterial and biofluid specimen contamination.
نویسندگان
چکیده
In this paper, the potential use of laser-induced breakdown spectroscopy (LIBS) for the rapid discrimination and identification of bacterial pathogens in realistic clinical specimens is investigated. Specifically, the common problem of sample contamination was studied by creating mixed samples to investigate the effect that the presence of a second contaminant bacterium in the specimen had on the LIBS-based identification of the primary pathogen. Two closely related bacterial specimens, Escherichia coli strain ATCC 25922 and Enterobacter cloacae strain ATCC 13047, were mixed together in mixing fractions of 10:1, 100:1, and 1000:1. LIBS spectra from the three mixtures were reliably classified as the correct E. coli strain with 98.5% accuracy when all the mixtures were withheld from the training model and classified against spectra from pure specimens. To simulate a rapid test for the presence of urinary tract infection pathogens, LIBS spectra were obtained from specimens of Staphylococcus epidermidis obtained from distilled water and sterile urine. LIBS spectra from the urine-harvested bacteria were classified as S. epidermidis with 100% accuracy when classified using a model containing only spectra from other Staphylococci species and with 88.5% accuracy when a model containing five genera of bacteria was utilized. Bacterial specimens comprising five different genera and 13 classifiable taxonomic groups of species and strains were compiled in a library that was tested using external validation techniques. The importance of utilizing external validation techniques where the library is tested with data withheld from all previous testing and training of the model was revealed by comparing the results against "leave-one-out" cross-validation results. Last, the effect of using sequential models for the classification of a single unknown spectrum was investigated by comparing the misclassification of two closely related bacteria, E. coli and E. cloacae, when the classification was first performed using the five-genus bacterial library and then with a smaller model consisting only of E. coli and E. cloacae specimens. This result shows the utility of using successively more targeted analyses and models that use preliminary classifications from more general models as input.
منابع مشابه
Towards the clinical application of laser-induced breakdown spectroscopy for rapid pathogen diagnosis: the effect of mixed cultures and sample dilution on bacterial identification
Laser-induced breakdown spectroscopy has been utilized to classify and identify bacterial specimens on the basis of their atomic composition. We have characterized the effect that the presence of a second bacterial species in the ablated specimen had on the identification of the majority species. Specimens with a reduced number of bacterial cells (approximately 2500) were identified with 100% a...
متن کاملThe effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کاملThe effect of bacterial environmental and metabolic stresses on a laser-induced breakdown spectroscopy (LIBS) based identification of Escherichia coli and Streptococcus viridans.
In this paper we investigate the effect that adverse environmental and metabolic stresses have on the laser-induced breakdown spectroscopy (LIBS) identification of bacterial specimens. Single-pulse LIBS spectra were acquired from a non-pathogenic strain of Escherichia coli cultured in two different nutrient media: a trypticase soy agar and a MacConkey agar with a 0.01% concentration of deoxycho...
متن کاملOptical Spectroscopic Methods to Discriminate in-Vitro Hodgkin Cancerous and Normal Tissues
Simultaneous laser induced- breakdown spectroscopy (LIBS) and acoustic response techniques as well as Laser induced fluorescence (LIF) are applied to investigate the abnormal lymph tissues due to Hodgkin disease. The spectral shift in the emissive fluorescence of the cancerous tissues has been observed respect to the normal ones. Regarding LIBS, the concentrations of Ca and Na trace elements ha...
متن کاملAnalysis of Cerebrospinal Fluid in Diagnosis of Bacterial Meningitis; Using Nuclear Magnetic Resonance Spectroscopy: A Systematic Review
Background: Analysis of biofluids provides a unique window into the biochemical status of a living organism since the composition of a given biofluid will be modulated according to the level of function of the cells that are intimately concerned with its manufacture and secretion. One of the most successful approaches to biofluid analysis has been the application of NMR spectroscopy. Objective...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 51 7 شماره
صفحات -
تاریخ انتشار 2012