Three-phase Load Signature: a wavelet-based approach to power analysis
نویسنده
چکیده
This paper presents an analysis of the load signature problem based on Park-domain instantaneous power definition. In particular, the Park power vector is analyzed in the wavelet domain. The analysis is performed by using two different bases to obtain information on the selection criteria. Different loads are analyzed and different challenges are discussed. The transient data are obtained via simulation by using a particular simulation platform called Virtual Test Bed.
منابع مشابه
Combined Use of Sensitivity Analysis and Hybrid Wavelet-PSO- ANFIS to Improve Dynamic Performance of DFIG-Based Wind Generation
In the past few decades, increasing growth of wind power plants causes different problems for the power quality in the grid. Normal and transient impacts of these units on the power grid clearly indicate the need to improve the quality of the electricity generated by them in the design of such systems. Improving the efficiency of the large-scale wind system is dependent on the control parameter...
متن کاملA Virtual Instrument for Time-Frequency Analysis of Park Power Components
Load signature analysis has been widely studied in the last ten years. It is possible to recognize a progressive growth of complexity in the approach adopted. One of the most significant changes has been the shift from quasi-steady-state analysis approaches to fully transient analysis. A case for this shift is well made in [1]. While the steadystate analysis of power components can be successfu...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملAn Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network
An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...
متن کامل