Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch.

نویسندگان

  • W X Ding
  • L Lin
  • J R Duff
  • D L Brower
  • J S Sarff
چکیده

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with ∼8 cm spacing. The source is a 432 μm (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k(⊥) < 1.3 cm(-1), corresponding k(⊥)ρ(s) < 1.3 (ρ(s) is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased Confinement and b by Inductive Poloidal Current Drive in the Reversed Field Pinch

With the addition of inductive poloidal current drive for current profile control in the Madison Symmetric Torus (MST) reversed field pinch, the magnetic fluctuation amplitude halves, leading to reduced energy and particle transport. A fourto five-fold increase in the energy confinement time to tE , 5 ms with both decreased Ohmic input power and increased stored thermal energy coincides with re...

متن کامل

Proposal of Density and Electrostatic Potential Fluctuation Measurements in the Madison Symmetric Torus with a Heavy Ion Beam Probe

A 200 keV heavy ion beam probe (HIBP) system is being installed on the Madison Symmetric Torus (MST) reversed eld pinch (RFP). Measurements of electron density uctuations and electrostatic potential uctuations in MST are proposed here. For the rst time particle transport induced by electrostatic eld uctuations in the core region of MST can be measured through the simultaneous measurement of ele...

متن کامل

Classical impurity ion confinement in a toroidal magnetized fusion plasma.

High-resolution measurements of impurity ion dynamics provide first-time evidence of classical ion confinement in a toroidal, magnetically confined plasma. The density profile evolution of fully stripped carbon is measured in MST reversed-field pinch plasmas with reduced magnetic turbulence to assess Coulomb-collisional transport without the neoclassical enhancement from particle drift effects....

متن کامل

Nonambipolar magnetic-fluctuation-induced particle transport and plasma flow in the MST reversed-field pinch.

First direct measurements of nonambipolar magnetic fluctuation-induced charge transport in the interior of a high-temperature plasma are reported. Global resistive tearing modes drive the charge transport which is measured in the vicinity of the resonant surface for the dominant core resonant mode. Finite charge transport has two important consequences. First, it generates a potential well alon...

متن کامل

Calibration of an advanced neutral particle analyzer for the Madison Symmetric Torus reversed-field pinch.

A new E∥B neutral particle analyzer, which has recently been installed on Madison Symmetric Torus (MST) reversed-field pinch (RFP), has now been calibrated, allowing the measurement of the fast ion density and energy distribution. This diagnostic, dubbed the advanced neutral particle analyzer (ANPA), can simultaneously produce time resolved measurements of the efflux of both hydrogen and deuter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 2012