Evaluation of the method for analyzing chromium, cobalt and titanium ion levels in the blood following hip replacement with a metal-on-metal prosthesis.

نویسندگان

  • Janie Barry
  • Martin Lavigne
  • Pascal-André Vendittoli
چکیده

High-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) can be used to measure metal ion levels in whole blood, although the accuracy and repeatability of this method is not yet known in the clinical setting. In this study, chromium, cobalt and titanium ion levels were measured in three whole blood samples, each collected at the same moment from 101 patients undergoing total hip arthroplasty with a metal-on-metal (MoM) bearing. The first sample (purge sample) had direct contact with the metal needle used during insertion of the catheter, whereas the second sample (reference sample) and the third sample (reserve sample) did not. The absolute difference between reference samples and reserve samples was greater than the limit of quantification of the HR-ICP-MS device for all three ions (0.84 versus 0.35 µg/L for chromium, 0.74 versus 0.07 for cobalt, and 0.88 versus 0.70 µg/L for titanium), although the levels were very small in most cases, they exceeded the clinical significant threshold in 19 to 31% of the cases. No clinically significant difference was observed between reference samples and purge samples. Therefore, HR-ICP-MS is a clinically acceptable method to evaluate metal ion levels in blood following hip replacement with an MoM prosthesis, and it is not necessary to discard the purge sample to obtain repeatable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallosis of the Resurfaced Hip

Metallosis of the hip is usually defined as aseptic fibrosis, local necrosis, or loosening of the prosthesis secondary to metallic corrosion and release of wear debris.8 It has also been defined as gray discoloration of the tissues of the joint, pain, an effusion, and elevated serum metal levels. Metallosis has been found with stainless steel, titanium, and cobalt chromium alloy femoral prosthe...

متن کامل

Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...

متن کامل

Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.

We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Meta...

متن کامل

Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 microg/L (0.4 to 5.5) for chromium and 0.67 microg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female ...

متن کامل

Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study.

Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2013