Diagnostic accuracy of magnetic resonance angiography for internal carotid artery disease: a systematic review and meta-analysis.

نویسندگان

  • Sarah M Debrey
  • Hua Yu
  • John K Lynch
  • Karl-Olof Lövblad
  • Violet L Wright
  • Sok-Ja D Janket
  • Alison E Baird
چکیده

BACKGROUND AND PURPOSE Accurate diagnosis of the degree of internal carotid artery (ICA) stenosis is needed for decisions regarding optimal stroke prevention. Noninvasive magnetic resonance angiography (MRA) is being proposed and used as a replacement for the gold standard, intra-arterial angiography. Our purpose was to perform a systematic review and diagnostic meta-analysis to determine the sensitivity and specificity of time-of-flight (TOF) MRA and contrast-enhanced (CE) MRA for the detection of (1) high-grade (> or = 70% to 99%) ICA stenoses; (2) ICA occlusions; (3) moderately severe (50% to 69%) ICA stenoses; and (4) compare the overall accuracy of the 2 MRA techniques. METHODS The medical literature on MRA and the diagnosis of ICA steno-occlusive disease was reviewed through the PubMed, EMBASE, and SCOPUS databases. All publication years were included through to November 2006. Studies were eligible for inclusion if they compared the accuracy of TOF or CE MRA for the detection of ICA disease against intra-arterial angiography and reported sufficient data. RESULTS The overall sensitivity of TOF MRA for the detection of > or = 70% to 99% ICA stenoses was 91.2% (95% CI: 88.9% to 93.1%) with a specificity of 88.3% (86.7% to 89.7%), whereas the sensitivity of CE MRA was 94.6% (92.4% to 96.4%) with a specificity of 91.9% (90.3% to 93.4%). For the detection of ICA occlusions, the sensitivity of TOF MRA was 94.5% (91.2% to 96.8%) and the specificity was 99.3% (98.9% to 99.6%), whereas the sensitivity and specificity values for CE MRA were 99.4% (96.8% to 100%) and 99.6% (99.2% to 99.9%), respectively. For moderately severe (50% to 69%) stenoses, TOF MRA had a sensitivity of only 37.9% (29.3% to 47.1%) and a specificity of 92.1% (89.6% to 94.1%); for CE MRA, the pooled sensitivity value was somewhat better at 65.9% (57.0% to 74.0%), whereas the specificity was 93.5% (91.3% to 95.3%). CONCLUSIONS TOF MRA and CE MRA showed high accuracy for the detection of high-grade ICA stenoses and occlusions with CE MRA having the edge over TOF MRA, but had only poor (TOF MRA) to fair (CE MRA) sensitivity for the detection of moderately severe stenoses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of magnetic resonance angiography for internal carotid artery disease.

Accuracy of Magnetic Resonance Angiography for Internal Carotid Artery Disease To the Editor: We read with great interest the article entitled “Diagnostic accuracy of magnetic resonance angiography for internal carotid artery disease: a systematic review and meta-analysis.”1 The authors made a comprehensive review and meta-analysis of many articles which compared magnetic resonance angiography ...

متن کامل

Use of magnetic resonance angiography to select candidates with recently symptomatic carotid stenosis for surgery: systematic review.

OBJECTIVE To determine if sufficient evidence exists to support the use of magnetic resonance angiography as a means of selecting patients with recently symptomatic high grade carotid stenosis for surgery. DESIGN Systematic review of published research on the diagnostic performance of magnetic resonance angiography, 1990-9. MAIN OUTCOME MEASURES Performance characteristics of diagnostic tes...

متن کامل

Contrast-enhanced three-dimensional magnetic resonance angiography of atherosclerotic internal carotid stenosis as the noninvasive imaging modality in revascularization decision making.

BACKGROUND AND PURPOSE In patients with severe internal carotid artery stenoses, thromboendarterectomy significantly reduces both ischemic stroke and the risk of more ischemic attacks. Digital subtraction angiography (DSA) is the accepted preoperative test to determine whether a high-grade stenosis is present and requires surgical therapy. However, DSA has a procedural risk of stroke between 0....

متن کامل

Vocal cord paralysis secondary to spontaneous internal carotid dissection: case report and systematic review of the literature

OBJECTIVES To present a rare case of unilateral vocal cord paralysis (VCP) secondary to spontaneous internal carotid artery dissection and to perform a literature review. CASE REPORT A 35-year-old male presented to the emergency department with acute onset hoarseness and dysphagia. History, physical exam and laryngoscopy revealed left sided VCP without obvious cause. Magnetic Resonance Imagin...

متن کامل

Constructive interference in steady state imaging of moyamoya disease.

The diagnostic accuracy of three-dimensional constructive interference in steady state (CISS) magnetic resonance (MR) imaging was evaluated for the assessment of idiopathic moyamoya disease. Six consecutive patients underwent MR angiography, CISS imaging, and digital subtraction angiography. MR angiography and CISS imaging visualization of the steno-occlusive changes in the distal internal caro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2008