Development of conventional and real-time nucleic acid sequence-based amplification assays for detection of Chlamydophila pneumoniae in respiratory specimens.

نویسندگان

  • K Loens
  • T Beck
  • H Goossens
  • D Ursi
  • M Overdijk
  • P Sillekens
  • M Ieven
چکیده

Isothermal nucleic acid sequence-based amplification (NASBA) was applied to the detection of Chlamydophila pneumoniae 16S rRNA by using the NucliSens basic kit (bioMérieux, Boxtel, The Netherlands). The assay was originally developed as a conventional NASBA assay with electrochemiluminescence detection and was subsequently adapted to a real-time NASBA format by using a molecular beacon. C. pneumoniae RNA prepared from a plasmid construct was used to assess the analytical sensitivity of the assay. The sensitivity of the NASBA assay was 10 molecules of in vitro wild-type C. pneumoniae RNA and 0.1 inclusion-forming unit (IFU) of C. pneumoniae. In spiked respiratory specimens, the sensitivity of the C. pneumoniae NASBA assay varied between 0.1 and 1 IFU/100 mul sample, depending on the type of specimen. Finally, conventional and real-time NASBA were applied to respiratory specimens previously tested by PCR. A 100% concordance between the test results was obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Mycoplasma pneumoniae by real-time nucleic acid sequence-based amplification.

Real-time isothermal nucleic acid sequence-based amplification (RT-NASBA) was applied to the detection of Mycoplasma pneumoniae. In vitro-generated M. pneumoniae RNA was used to assess the sensitivity of the assay. The 95% hit rate was 148 molecules of M. pneumoniae RNA in the amplification and 10(4) molecules of in vitro-generated RNA after nucleic acid extraction. The sensitivity of the RT-NA...

متن کامل

Evaluation of Nucleic Acid Sequence Based Amplification (NASBA) and Reverse Transcription Polymerase Chain Reaction for Detection of Coxsackievirus B3 in Cell Culture and Animal Tissue Samples

Enteroviruses are the causative agents of a number of diseases in humans. Group B coxsackieviruses are believed to be the most common viral agents responsible for human heart disease. Genomic data of enteroviruses has allowed developing new molecular approaches such as Nucleic Acid Sequence Based Amplification (NASBA) for detection of such viruses. In this study, coxsackievirus B3 (CVB3) was de...

متن کامل

Detection of 11 common viral and bacterial pathogens causing community-acquired pneumonia or sepsis in asymptomatic patients by using a multiplex reverse transcription-PCR assay with manual (enzyme hybridization) or automated (electronic microarray) detection.

Community-acquired pneumonia (CAP) and sepsis are important causes of morbidity and mortality. We describe the development of two molecular assays for the detection of 11 common viral and bacterial agents of CAP and sepsis: influenza virus A, influenza virus B, respiratory syncytial virus A (RSV A), RSV B, Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, Legionella micda...

متن کامل

Comparison and evaluation of real-time PCR, real-time nucleic acid sequence-based amplification, conventional PCR, and serology for diagnosis of Mycoplasma pneumoniae.

Mycoplasma pneumoniae is a common cause of community-acquired pneumonia and lower-respiratory-tract infections. Diagnosis has traditionally been obtained by serological diagnosis, but increasingly, molecular techniques have been applied. However, the number of studies actually comparing these assays is limited. The development of a novel duplex real-time PCR assay for detection of M. pneumoniae...

متن کامل

Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.

The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same sam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 2006