Thermoelectrically cooled quantum-cascade-laser-based sensor for the continuous monitoring of ambient atmospheric carbon monoxide.

نویسندگان

  • Anatoliy A Kosterev
  • Frank K Tittel
  • Rüdeger Köhler
  • Claire Gmachl
  • Federico Capasso
  • Deborah L Sivco
  • Alfred Y Cho
  • Shawn Wehe
  • Mark G Allen
چکیده

We report the first application of a thermoelectrically cooled, distributed-feedback quantum-cascade laser for continuous spectroscopic monitoring of CO in ambient air at a wavelength of 4.6 microm. A noise-equivalent detection limit of 12 parts per billion was demonstrated experimentally with a 102-cm optical pathlength and a 2.5-min data acquisition time at a 10-kHz pulsed-laser repetition rate. This sensitivity corresponds to a standard error in fractional absorbance of 3 x 10(-5).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy

A nitric oxide (NO) gas sensor based on a thermoelectrically cooled, continuous-wave, distributed feedback quantum cascade laser operating at 5.45 μm (1835 cm−1) and off-axis integrated cavity output spectroscopy combined with a wavelength-modulation technique was developed to determine NO concentrations at the sub-ppbv levels that are essential for a number of applications, such as medical dia...

متن کامل

Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelectrically cooled, continuous-wave quantum cascade laser.

We used a thermoelectrically cooled, continuous-wave, quantum cascade laser operating between 1847 and 1854 cm(-1) in combination with wavelength modulation spectroscopy for the detection of nitric oxide (NO) at the sub-part-per-billion by volume (ppbv) level. The laser emission overlaps the P7.5 doublet of NO centered around 1850.18 cm(-1). Using an astigmatic multiple-pass absorption cell wit...

متن کامل

Atmospheric CH₄ and N₂O measurements near Greater Houston area landfills using a QCL-based QEPAS sensor system during DISCOVER-AQ 2013.

A quartz-enhanced photoacoustic absorption spectroscopy (QEPAS)-based gas sensor was developed for methane (CH₄) and nitrous-oxide (N₂O) detection. The QEPAS-based sensor was installed in a mobile laboratory operated by Aerodyne Research, Inc. to perform atmospheric CH₄ and N₂O detection around two urban waste-disposal sites located in the northeastern part of the Greater Houston area, during D...

متن کامل

Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas

We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH(2)O) using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 μm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm(-1) is selected for CH(2)...

متن کامل

Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum-cascade distributed feedback laser.

A compact ammonia sensor based on a 10-microm single-frequency, thermoelectrically cooled, pulsed quantum-cascade laser with an embedded distributed feedback structure has been developed. To measure NH3 concentrations, we scanned the laser over two absorption lines of its fundamental v2 band. A sensitivity of better than 0.3 parts per million was achieved with just a 1-m optical path length. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2002