Hs8 Saturation Pulse Train for First-pass Myocardial Perfusion Imaging at 7t
نویسندگان
چکیده
Purpose: First-pass myocardial perfusion imaging is used clinically but would benefit from improved image quality. These improvements might be expected at 7T due to higher signal to noise ratio and longer T1 of the myocardium. But major implementation challenges at 7T are found owing to the large B0&B1 variations across the heart, low peak B1, and SAR restrictions that make uniform saturation extremely difficult to achieve. We propose a train of four HS8 pulses for saturation in first-pass myocardial perfusion imaging at 7T, and compare it with previously proposed solutions in simulation and in-vivo experiments. We also present the first series of human first-pass myocardial perfusion images at 7T.
منابع مشابه
Optimized Saturation Pulse Train for Human First-Pass Myocardial Perfusion Imaging at 7T
PURPOSE To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS The new design of saturation pulse train consists of four hyperbolic-secant (HS8) radiofrequency pulses, whose peak amplitudes are optimized f...
متن کاملHybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.
Uniform T(1)-weighting is a major challenge for first-pass cardiac perfusion MRI at 3 T. Previously proposed adiabatic amplitude of radiofrequency field (B(1))-insensitive rotation (BIR-4) pulse and standard and tailored pulse trains of three nonselective pulses have been important developments but each pulse has limitations at 3 T. As an extension of the tailored pulse train, we developed a hy...
متن کاملFirst-pass myocardial perfusion imaging with whole ventricular coverage using L1-SPIRIT accelerated spiral trajectories
Background First-pass perfusion imaging using cardiac magnetic resonance (CMR) has become clinically applicable as an important tool for diagnosing coronary artery disease. We have recently demonstrated that high quality firstpass images can be acquired with an optimized spiral pulse sequence, but this sequence is only capable of imaging 3 short axis slices of the heart for a maximum heart rate...
متن کامل3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses.
PURPOSE To compare myocardial enhancement during first-pass myocardial perfusion imaging at 3.0 Tesla (T) and 1.5T. MATERIALS AND METHODS First-pass myocardial perfusion imaging was performed on twelve normal subjects at 3T and 1.5T using an interleaved notched saturation recovery gradient echo pulse sequence. Subjects received either 0.10 mmol/kg for both scans (group 1), 0.075 mmol/kg for b...
متن کاملImaging sequences for first pass perfusion --a review.
Myocardial perfusion imaging sequences and analysis techniques continue to improve. We review the state-of-the-art in cardiovascular magnetic resonance first pass perfusion pulse sequences including the application of parallel imaging. There are a wide range of sequence designs and parameters to consider when optimizing an acquisition protocol. The interdependence of these parameters forces the...
متن کامل