Identifying the procedural gap and improved methods for maintaining accuracy during total hip arthroplasty.

نویسندگان

  • Allan Gross
  • Jeffrey M Muir
چکیده

Osteoarthritis is a ubiquitous condition, affecting 26 million Americans each year, with up to 17% of adults over age 75 suffering from one variation of arthritis. The hip is one of the most commonly affected joints and while there are conservative options for treatment, as symptoms progress, many patients eventually turn to surgery to manage their pain and dysfunction. Early surgical options such as osteotomy or arthroscopy are reserved for younger, more active patients with less severe disease and symptoms. Total hip arthroplasty offers a viable solution for patients with severe degenerative changes; however, post-surgical discrepancies in leg length, offset and component malposition are common and cause significant complications. Such discrepancies are associated with consequences such as low back pain, neurological deficits, instability and overall patient dissatisfaction. Current methods for managing leg length and offset during hip arthroplasty are either inaccurate and susceptible to error or are cumbersome, expensive and lengthen surgical time. There is currently no viable option that provides accurate, real-time data to surgeons regarding leg length, offset and cup position in a cost-effective manner. As such, we hypothesize that a procedural gap exists in hip arthroplasty, a gap into which fall a large majority of arthroplasty patients who are at increased risk of complications following surgery. These complications and associated treatments place significant stress on the healthcare system. The costs associated with addressing leg length and offset discrepancies can be minor, requiring only heel lifts and short-term rehabilitation, but can also be substantial, with revision hip arthroplasty costs of up to $54,000 per procedure. The need for a cost-effective, simple to use and unobtrusive technology to address this procedural gap in hip arthroplasty and improve patient outcomes is of increasing importance. Given the aging of the population, the projected increases in the volume of procedures over the coming decades and the economic pressures associated with downward pricing pressure and bundled payments, the need to address this gap is underscored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty

Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Functional Mobility and Balance After Total Hip Arthroplasty and Healthy Elders

Objectives: The purpose of this study was to determine the functional mobility and balance in the elders after Total Hip Arthroplasty in healthy coparison to elders. Methods & Materials: The current cross-sectional study was done on 20 patients (70.9±4.2) with hip osteoarthritis 6 months after Total Hip Arthroplasty and 20 healthy subjects (73±5.7) as control group. Patient group was assigne...

متن کامل

Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30

Background:  We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30.   Methods:  Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications.   Results:  Within a mean fol...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical hypotheses

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2016