Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.
نویسندگان
چکیده
BACKGROUND Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. METHODS Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. RESULTS Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. CONCLUSIONS Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.
منابع مشابه
Systematic review of studies evaluating urinary iodine concentration as a predictor of 24-hour urinary iodine excretion for estimating population iodine intake.
OBJECTIVE To examine the usefulness of "spot" urine iodine concentrations (UICs) in predicting 24-hour urine iodine excretion (UIE) for estimating average population iodine intake. METHODS An electronic literature search was conducted for articles published through 19 May 2013 in MEDLINE (from 1950), EMBASE (from 1980), and the Cochrane Library (from 1993) using the terms "urinary excretion (...
متن کاملUrinary excretion of sodium, potassium, and chloride, but not iodine, varies by timing of collection in a 24-hour calibration study.
Because of the logistic complexity, excessive respondent burden, and high cost of conducting 24-h urine collections in a national survey, alternative strategies to monitor sodium intake at the population level need to be evaluated. We conducted a calibration study to assess the ability to characterize sodium intake from timed-spot urine samples calibrated to a 24-h urine collection. In this rep...
متن کاملمقایســه اندازهگیری سطح آلبومین به روش ایمونوتوربیدومتری در ســه شیوه مختلف نـمونهگیری ادراری برای غربالگری آلبومینوری در بیماران دیابتی
Background: Microalbominuria (MA) is early presentation of renal damage which acts as an independent factor of cardiovascular events in these patients. There are various methods for sampling and also different laboratory tests to measuring albominuria. The aim of this study was to compare of different urine collection methods for measuring albominuria using immunoturbidometry assay which has a...
متن کاملSystematic review of studies comparing 24-hour and spot urine collections for estimating population salt intake.
OBJECTIVE To examine the usefulness of urine sodium (Na) excretion in spot or timed urine samples to estimate population dietary Na intake relative to the gold standard of 24-hour (h) urinary Na. METHODS An electronic literature search was conducted of MEDLINE (from 1950) and EMBASE (from 1980) as well as the Cochrane Library using the terms "sodium," "salt," and "urine." Full publications of...
متن کاملEstimation of iodine intake from various urinary iodine measurements in population studies.
BACKGROUND Iodine intake is often measured by a surrogate measure, namely urine iodine excretion as almost all ingested iodine is excreted in the urine. However, the methods for urine collection and the reporting of the results vary. These methods, and their advantages and disadvantages, are considered in this article. SUMMARY There are two main ways in which urine can be collected for iodine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thyroid : official journal of the American Thyroid Association
دوره 24 4 شماره
صفحات -
تاریخ انتشار 2014