Reliable intraocular pressure measurement using automated radio-wave telemetry

نویسندگان

  • Eleftherios I Paschalis
  • Fabiano Cade
  • Samir Melki
  • Louis R Pasquale
  • Claes H Dohlman
  • Joseph B Ciolino
چکیده

PURPOSE To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. METHODS The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. RESULTS On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. CONCLUSION IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure measurement by radio wave telemetry.

PURPOSE To determine the biocompatibility of a new wireless intraocular pressure (IOP) transducer (WIT) in rabbit eyes and to correlate its measurements with other pressure-measuring devices. METHODS The WIT is a ring-shaped intraocular device that allows wireless IOP measurements through radiofrequency. It was implanted into six eyes of New Zealand White rabbits after extracapsular lens extr...

متن کامل

Tail‐Cuff Technique and Its Influence on Central Blood Pressure in the Mouse

BACKGROUND Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of th...

متن کامل

Evaluation of Automated Radio Telemetry for Quantifying Movements and Home Ranges of Snakes

—We evaluated an automated telemetry system that can dramatically increase the amount of activity and spatial data collected for snakes. We developed methods for analyzing data from single automated receiving units (ARUs) and ARU arrays, compared results from ARUs with conventional hand tracking, and assessed previously untested assumptions used in conventional telemetry, using data from ratsna...

متن کامل

Measurement of intraocular pressure by telemetry in conscious, unrestrained rabbits.

PURPOSE The aim of this study was to develop a system for the continuous recording of the intraocular pressure (IOP) in rabbits maintained in their normal environment. A telemetric system originally designed for the measurement of cardiovascular parameters in unrestrained, conscious laboratory animals was adapted for this purpose. METHODS Experiments were performed in adult albino female rabb...

متن کامل

A miniature bidirectional telemetry system for in vivo gastric slow wave recordings.

Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014