[18F]FDG-PET as an imaging biomarker to NMDA receptor antagonist-induced neurotoxicity.
نویسندگان
چکیده
Positron emission tomography (PET) is an effective tool for noninvasive examination of the body and provides a range of functional information. PET imaging with [(18)F]fluoro-2-deoxy-d-glucose ([(18)F]FDG) has been used to image alterations in glucose metabolism in brain or cancer tissue in the field of clinical diagnosis but not in the field of toxicology. A single dose of N-methyl-d-aspartate (NMDA) receptor antagonist induces neuronal cell degeneration/death in the rat retrosplenial/posterior cingulate (RS/PC) cortex region. These antagonists also increase local cerebral glucose utilization. Here, we examined the potential of [(18)F]FDG-PET as an imaging biomarker of neurotoxicity induced by an NMDA receptor antagonist, MK-801. Using [(18)F]FDG-PET, we determined that increased glucose utilization involved the neurotoxicity induced by MK-801. The accumulation of [(18)F]FDG was increased in the rat RS/PC cortex region showing neuronal cell degeneration/death and detected before the onset of neuronal cell death. This effect increased at a dose level at which neuronal cell degeneration recovered 24h after MK-801 administration. Scopolamine prevented the neurotoxicity and [(18)F]FDG accumulation induced by MK-801. Furthermore, in cynomolgus monkeys that showed no neuronal cell degeneration/death when treated with MK-801, we noted no differences in [(18)F]FDG accumulation between test and control subjects in any region of the brain. These findings suggest that [(18)F]FDG-PET, which is available for clinical trials, may be useful in generating a predictive imaging biomarker for detecting neurotoxicity against NMDA receptor antagonists with the same pharmacological activity as MK-801.
منابع مشابه
Generalized lymph node activation after Influenza vaccination on 18F FDG-PET/CT imaging, an important pitfall in PET interpretation
We report on a 59-year-old female patient with an infected vascular graft investigated with 18F FDG-PET/CT. The first of two studies showed FDG activity in the left deltoid and ipsilateral axillary lymph nodes explained by influenza vaccination the day prior. The second 18F FDG-PET/CT showed multiple FDG-avid lymph nodes on both sides of the diaphragm without tracer accumulation at the vaccinat...
متن کامل18F-FDG PET/CT in the diagnosis of tumor thrombus from anaplastic thyroid carcinoma in a young boy
Anaplastic thyroid carcinoma is an uncommon, highly aggressive malignancy usually presenting in the elderly. An eighteen year old boy was recently diagnosed as anaplastic carcinoma of the thyroid. PET/CECT scan performed for staging, revealed a large FDG avid heterogeneously enhancing thyroid mass with bilateral jugular venous thrombosis, which also showed increase...
متن کاملDiagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary
Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...
متن کاملFactors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging
Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...
متن کاملImplementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Toxicological sciences : an official journal of the Society of Toxicology
دوره 133 1 شماره
صفحات -
تاریخ انتشار 2013