Internal fixation for displaced fractures of the femoral neck. Does bone density affect clinical outcome?
نویسندگان
چکیده
The results of meta-analysis show a revision rate of 33% for internal fixation of displaced fractures of the femoral neck, mostly because of nonunion. Osteopenia and osteoporosis are highly prevalent in elderly patients. Bone density has been shown to correlate with the intrinsic stability of the fixation of the fracture in cadaver and retrospective studies. We aimed to confirm or refute this finding in a clinical setting. We performed a prospective, multicentre study of 111 active patients over 60 years of age with a displaced fracture of the femoral neck which was eligible for internal fixation. The bone density of the femoral neck was measured pre-operatively by dual-energy x-ray absorptiometry (DEXA). The patients were divided into two groups namely, those with osteopenia (66%, mean T-score -1.6) and those with osteoporosis (34%, mean T-score -3.0). Age (p = 0.47), gender (p = 0.67), delay to surgery (p = 0.07), the angle of the fracture (p = 0.33) and the type of implant (p = 0.48) were similar in both groups. Revision to arthroplasty was performed in 41% of osteopenic and 42% of osteoporotic patients (p = 0.87). Morbidity (p = 0.60) and mortality were similar in both groups (p = 0.65). Our findings show that the clinical outcome of internal fixation for displaced fractures of the femoral neck does not depend on bone density and that pre-operative DEXA is not useful.
منابع مشابه
Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration.
BACKGROUND Intracapsular femoral neck fractures are associated with high rates of nonunion. We aimed to identify risk factors for nonunion in patients with both displaced and nondisplaced intracapsular femoral neck fractures treated with three 7-mm parallel cannulated screws, placed in either a triangle or an inverted triangle configuration, using failure of fixation as the primary outcome. M...
متن کاملMinimally displaced intra-capsular femoral neck fractures in the elderly--comparison of multiple threaded pins and sliding compression screws surgical techniques.
PURPOSE To determine the outcome of treatment for minimally displaced femoral neck fractures using multiple threaded pins versus sliding compression screws for internal fixation. METHODS The medical records of 62 consecutive elderly patients with minimally displaced intra-capsular femoral neck fractures who underwent internal fixation of the fracture (37 with multiple threaded pins, and 25 wi...
متن کاملClinical outcome after undisplaced femoral neck fractures
BACKGROUND AND PURPOSE Little attention has been paid to undisplaced femoral neck fractures. By using data from the Norwegian Hip Fracture Register, we investigated the risk of reoperation and the clinical outcome after treatment of these fractures in patients over 60 years of age. METHODS Data on 4,468 patients with undisplaced femoral neck fractures who were operated with screw osteosynthes...
متن کاملThe use of surgery in displaced scapular neck fractures.
OBJECTIVES To evaluate the use of surgical management in displaced scapular neck fractures. SUBJECTS AND METHODS 14 adult male patients (average age 34 years, range 19-44) with displaced scapular neck fractures were treated by open reduction and internal fixation in Al-Jahra Hospital, Kuwait from April 2000 to January 2004. Patients' clinical and radiological results were analyzed retrospecti...
متن کاملInternal fixation of femoral neck stress fractures in young female athletes with a dynamic locking plate.
PURPOSE Displaced stress fractures of the femoral neck in young female athletes are a rare but a difficult injury to treat with a favourable outcome, as there is a reported high incidence of avascular necrosis. Traditionally they are internally fixed with either cannulated screws or a sliding hip screw. Our study aims to highlight the Targon Femoral Neck (FN, B-Braun, Aesculap Inc, Germany) imp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2005