Static two-dimensional aperture coding for multimodal, multiplex spectroscopy.

نویسندگان

  • Michael E Gehm
  • Scott T McCain
  • Nikos P Pitsianis
  • David J Brady
  • Prasant Potuluri
  • Michael E Sullivan
چکیده

We propose a new class of aperture-coded spectrometer that is optimized for the spectral characterization of diffuse sources. The instrument achieves high throughput and high spectral resolution by replacing the slit of conventional dispersive spectrometers with a more complicated spatial filter. We develop a general mathematical framework for deriving the required aperture codes and discuss several appealing code families. Experimental results validate the performance of the instrument.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multimodal, multiplex, Raman spectroscopy of alcohol in diffuse, fluorescent media

Optical diagnostics in biological materials are hindered by fluorescence and scattering. We have developed a multimodal, multiplex, coded-aperture Raman spectrometer to detect alcohol in a lipid tissue phantom solution.

متن کامل

Performance comparison of aperture codes for multimodal, multiplex spectroscopy.

We experimentally evaluate diverse static independent column codes in a coded aperture spectrometer. The performance of each code is evaluated based on the signal-to-noise ratio (SNR), defined as the peak value in the spectrum to the standard deviation of the background noise, as a function of subpixel vertical misalignments. Among the code families tested, an S-matrix-based code produces spect...

متن کامل

Longwave infrared (LWIR) coded aperture dispersive spectrometer.

We describe a static aperture-coded, dispersive longwave infrared (LWIR) spectrometer that uses a microbolometer array at the detector plane. The two-dimensional aperture code is based on a row-doubled Hadamard mask with transmissive and opaque openings. The independent column code nature of the matrix makes for a mathematically well-defined pattern that spatially and spectrally maps the source...

متن کامل

Two-dimensional aperture coding for magnetic sector mass spectrometry.

In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many yea...

متن کامل

Multimodal multiplex Raman spectroscopy optimized for in vivo chemometrics

We have designed and constructed a multimodal multiplex Raman spectrometer which uses multi-wavelength excitation to better detect signals in the presence of fluorescence by taking advantage of the shift-variance of the Raman signal with respect to excitation frequency. Coupled with partial-least-squares (PLS) regression, the technique applied to ethanol estimation in a tissue phantom achieves ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 45 13  شماره 

صفحات  -

تاریخ انتشار 2006