Helical TomoTherapy versus sterotactic Gamma Knife radiosurgery in the treatment of single and multiple brain tumors: a dosimetric comparison

نویسندگان

  • Tushar Kumar
  • Joseph Rakowski
  • Bo Zhao
  • Mazin Alkhafaji
  • Jacob Burmeister
  • Tammy Austin
  • Maria Vlachaki
چکیده

The objective was to compare the dosimetry of Helical TomoTherapy (TOMO) and Gamma Knife (GK) treatment plans for tumor and normal brain in the treatment of single and multiple brain tumors. An anthropomorphic Rando Head phantom was used to compare the dosimetry of TOMO and GK. Eight brain tumors of various shapes, sizes and locations were used to generate 10 plans. The radiation dose was 20 Gy prescribed to the 100% isodose line for TOMO plans and to the 50% for the GK plans. Dose Volume Histograms for tumor and brain were compared. Equivalent Uniform Dose (gEUD), Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) were performed and used for plan comparisons. Average minimum, mean, median and maximum tumor doses were 19.93, 27.83, 27.38, 39.60 Gy for GK and 20.17, 20.60, 20.59, 20.90 Gy for TOMO. Average gEUD values for tumor and normal brain were 25.0 and 7.2 Gy for GK and 20.7 and 8.1 Gy for TOMO. Conformity indices (CI) were similar for both modalities. Gradient indices (GI) were greater for TOMO. A combination plan was also generated using all eight tumors. TOMO was able to target all eight tumors simultaneously resulting in mean tumor and brain doses of 20.5 and 9.35 Gy, respectively. Due to the maximum limit of 50 beams per plan, GK was unable to provide a treatment plan for all eight tumors. GK provides an advantage for all tumor sizes with respect to tumor and normal brain dose. Clinical studies are needed to correlate these dosimetric findings with patient outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis

BACKGROUND Helical Tomotherapy (HT) integrates linear accelerator and computerized tomography (CT) technology to deliver IMRT. Targets are localized (i.e. outlined as gross tumor volume [GTV] and planning target volume [PTV]) on the planning kVCT study while daily MVCT is used for correction of patient's set-up and assessment of inter-fraction anatomy changes. Based on dosimetric comparisons, t...

متن کامل

Gamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data

Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...

متن کامل

Comparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

متن کامل

Effect of Treatment Modality on the Hypothalamic–Pituitary Function of Patients Treated with Radiation Therapy for Pituitary Adenomas: Hypothalamic Dose and Endocrine Outcomes

BACKGROUND Both fractionated external beam radiotherapy and single fraction radiosurgery for pituitary adenomas are associated with the risk of hypothalamic-pituitary (HP) axis dysfunction. OBJECTIVE To analyze the effect of treatment modality (Linac, TomoTherapy, or gamma knife) on hypothalamic dose and correlate these with HP-axis deficits after radiotherapy. METHODS Radiation plans of pa...

متن کامل

Nursing perspective of gamma knife of treatment

Gamma knife is a new noninvasive method for treatment of patient with brain tumors. ‎Another name of this procedure is steriotatic radiosurgery.‎‏ ‏This computerized advanced ‎technique was implicated by a team including neurosurgeon, neuroradialogist, oncologist, and ‎a nurse. This method is used for treatment of certain brain tumors and lesions. The benefits are ‎l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010