T1W4: A High-Performance Scintillator-Silicon-Well X-Rays Microdetector Based on DRIE Techniques

نویسندگان

  • J. G. Rocha
  • J. H. Correia
چکیده

This paper describes a X-rays detector based on an array of scintillator crystals, CsI:Tl, encapsulated in well-type silicon. The X-ray energy is first converted to visible light which is detected by a photodetector in the well bottom. DRIE techniques are used to achieve perfect vertical sidewalls 515 m deep, 100 m pixel square size and to maximize the fill factor. The inner walls of the well are electroplated with aluminum for improving the number of photons arriving in the detector and to reduce cross-talk between adjacent wells. Simulations and modeling show an improvement of approximately 26% in the detection efficiency using an aluminum layer 5 m thick.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

VERY DEEP TRENCHES IN SILICON WAFER USING DRIE METHOD WITH ALUMINUM MASK

Abstract: In this paper, a DRIE process for fabricating MEMS silicon trenches with a depth of more than 250 m is described. The DRIE was produced in oxygen-added sulfur hexafluoride (SF6) plasma, with sample cooling to cryogenic temperature using a Plasmalab System 100 ICP 180 at different RF powers. A series of experiments were performed to determine the etch rate and selectivity of the some m...

متن کامل

Design and construction of the Mini-Calorimeter of the AGILE satellite

AGILE is a small space mission of the Italian Space Agency (ASI) devoted to gamma-ray and hard-X astrophysics, successfully launched on April 23 2007. The AGILE Payload is composed of three instruments: a gamma-ray imager based on a tungsten-silicon tracker (ST), for observations in the gamma ray energy range 30 MeV 50 GeV, a Silicon based X-ray detector, SuperAGILE (SA), for imaging in the ran...

متن کامل

GLAST LAT silicon tracker

The Large Area Telescope (LAT) on the Gamma-ray Large-Area Space Telescope (GLAST) mission is designed to provide unprecedented sensitivity in the exploration of the gamma-ray sky. Gamma rays with energy above 10 MeV are detected via the pair conversion process, using a precision silicon tracker-converter and a hodoscopic CsI calorimeter. Charged cosmic rays are rejected by a tiled plastic-scin...

متن کامل

The influence of electron multiplication and internal X-ray fluorescence on the performance of a scintillator-based gamma camera

When considering the ‘standard’ gamma-camera, one might picture an array of photo-multiplier tubes or a similar array of small-area detectors. This array of imaging detectors would be attached to a corresponding array of scintillator modules (or a solid layer of scintillator) in order to give a high detection efficiency in the energy region of interest, usually 8-140 keV. Over recent years, dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000