Studies of charge transfer at liquid liquid interfaces and bilayer lipid membranes by scanning electrochemical microscopy
نویسندگان
چکیده
The principles of scanning electrochemical microscopy (SECM) and its application to studies of electron transfer at the interface between two immiscible electrolyte solutions are reviewed. The results of SECM measurements with a number of redox couples at the bare liquid liquid interface or an interface with a lipid monolayer suggest that the electron transfer follows that predicted by Marcus theory, with evidence for an inverted region. The SECM can also be used to probe processes at bilayer lipid membranes. © 2000 Elsevier Science S.A. All rights reserved.
منابع مشابه
Scanning electrochemical microscopy. 38. Application of SECM to the study of charge transfer through bilayer lipid membranes.
The use of the scanning electrochemical microscope (SECM) to probe the kinetics of charge-transfer processes at bilayer lipid membranes (BLM) is presented. Analysis of the SECM tip response demonstrates that an unmodified BLM behaves as an insulator, whereas a BLM doped with iodine shows some positive feedback. The SECM technique thus allows one to probe processes at a BLM and determine the kin...
متن کاملNumerical Study of Electro-thermo-convection in a Differentially Heated Cavity Filled with a Dielectric Liquid Subjected to Partial Unipolar Injection
The Coulomb force applied by an electric field on any charge present in a dielectric liquid may cause fluid motion. At high applied electric fields in an insulating liquid, electric charge carriers are created at metallic/liquid interfaces, a process referred to as ion injection, and result from electrochemical reactions. In this article we deals with the problem of electro thermal convection i...
متن کاملElectrochemistry at Electrified Soft Interfaces – Novel Approaches to Old Problems
This thesis addresses some known difficulties in the field of liquid | liquid electrochemistry by presenting novel means of controlling mass transfer, monolayermodification of the interface, and probing interfacial reactivity. A novel rectangular channel flow electrochemical cell suitable for studying charge transfer at liquid | liquid interfaces is presented. The organic phase is immobilised u...
متن کاملScanning electrochemical microscopy. 40. Voltammetric ion-selective micropipet electrodes for probing ion transfer at bilayer lipid membranes.
Voltammetric ion-selective micropipet electrodes for use in scanning electrochemical microscopy (SECM) for detection of potassium ion were fabricated. These used pulled borosilicate capillaries with tip orifice radii of 0.7-20 microm with silanized inner walls filled with a solution of 10 mM valinomycin and 10 mM ETH 500 in dichloroethane. The electrodes were characterized by determining the st...
متن کاملScanning Electrochemical Microscopy Studies of Electron Transfer through Monolayers Containing Conjugated Species at the Liquid-Liquid Interface
Theratesof electron transfer (ET)betweentworedoxspecies throughamonolayerof saturateddipalmytoyl phosphocholine and polyconjugated 2(3-(diphenylhexatrienyl)propanoyl)-1-hexadecanoyl-sn-glycero-3phosphocholine phospholipids adsorbed at the interface of two immiscible electrolyte solutions (ITIES) were measured by scanning electrochemical microscopy. Comparison of the ET rates shows that addition...