IOFF generally extends fluorophore longevity in the presence of an optical trap.

نویسندگان

  • J M Ferrer
  • D Fangyuan
  • R R Brau
  • P B Tarsa
  • M J Lang
چکیده

The combination of optical tweezers force microscopy and single molecule fluorescence has previously been complicated by trap-induced photobleaching. Recent studies have suggested that this effect is caused by a sequential absorption of photons, leading to ionization of the fluorescent singlet state. In this work, we show the range of effects of optical trapping radiation on common fluorescent dyes. Using the interlaced optical force fluorescence (IOFF) laser modulation technique, we show that the removal of simultaneous near infrared radiation dramatically reduces photobleaching effects. However, these studies show that the sequential addition of near infrared radiation in some cases extends photobleaching longevity beyond the natural intrinsic decay. We suggest a refined photoelectronic mechanism that accounts for the possibility of reverse intersystem crossing from a reactive triplet state and explains the nature of trap-induced photobleaching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interlaced optical force-fluorescence measurements for single molecule biophysics.

Combining optical tweezers with single molecule fluorescence offers a powerful technique to study the biophysical properties of single proteins and molecules. However, such integration into a combined, coincident arrangement has been severely limited by the dramatic reduction in fluorescence longevity of common dyes under simultaneous exposure to trapping and fluorescence excitation beams. We p...

متن کامل

The effect of integration time on fluctuation measurements: calibrating an optical trap in the presence of motion blur.

Dynamical instrument limitations, such as finite detection bandwidth, do not simply add statistical errors to fluctuation measurements, but can create significant systematic biases that affect the measurement of steady-state properties. Such effects must be considered when calibrating ultra-sensitive force probes by analyzing the observed Brownian fluctuations. In this article, we present a nov...

متن کامل

Single-molecule gold-nanoparticle tracking.

Gold nanoparticles, like single fluorophores, can be used to locate single molecules with nanometer accuracy. Unlike an optical trap, the gold particle label does not exert an external load, which is important for studying diffusive processes. Thus, a gold particle can be used analogously to a single fluorophore, providing similar information but with submillisecond time resolution. The feature...

متن کامل

Tuning the Luminescence of CdS Quantum Dots by a Simple Method

In this report, we present a facile approach for the synthesis of luminescent CdS and CdS:Mn+2 nanocrystals by reaction of CdSO4 and Na2S2O3 in the presence of thioglycerol (C3H8O2S) as capping agent. The influence of various experimental variables including, pH values and percentage of dopant, on the growth...

متن کامل

A study on Isatis suspension trap efficiency; Advantages and disadvantages

Different types of sediment trap have been introduced so far to be used in erosion measuring stations, each with its own advantages and disadvantages in trapping aeolian particles. These traps have different collection and retention efficiency due to aerodynamic conditions. Some characteristics such as isokinetic feature of the trap, collection efficiency, time needed to download sediment, capa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current pharmaceutical biotechnology

دوره 10 5  شماره 

صفحات  -

تاریخ انتشار 2009