Exposure level and distribution characteristics of airborne bacteria and fungi in Seoul metropolitan subway stations.
نویسندگان
چکیده
The exposure level and distribution characteristics of airborne bacteria and fungi were assessed in the workers' activity areas (station office, bedroom, ticket office and driver's seat) and passengers' activity areas (station precinct, inside the passenger carriage, and platform) of the Seoul metropolitan subway. Among investigated areas, the levels of airborne bacteria and fungi in the workers' bedroom and station precincts were relatively high. No significant difference was found in the concentration of airborne bacteria and fungi between the underground and above ground activity areas of the subway. The genera identified in all subway activity areas with a 5% or greater detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium for airborne bacteria and Penicillium, Cladosporium, Chrysosporium, Aspergillus for airborne fungi. Staphylococcus and Micrococcus comprised over 50% of the total airborne bacteria and Penicillium and Cladosporium comprised over 60% of the total airborne fungi, thus these four genera are the predominant genera in the subway station.
منابع مشابه
Statistical Analysis of the Metropolitan Seoul Subway System: Network Structure and Passenger Flows
The Metropolitan Seoul Subway system, consisting of 380 stations, provides the major transportation mode in the metropolitan Seoul area. Focusing on the network structure, we analyze statistical properties and topological consequences of the subway system. We further study the passenger flows on the system, and find that the flow weight distribution exhibits a power-law behavior. In addition, t...
متن کاملDistribution of airborne bacteria in railway stations in Tokyo, Japan.
OBJECTIVES We performed the current study to (1) understand the distribution of culturable airborne bacteria over a one-year monitoring period, (2) confirm places in stations where airborne bacteria are highly detected, (3) understand the factors that affect concentrations of airborne bacteria and (4) compare the distributions of airborne bacteria and fungi in railway stations in Japan. METHO...
متن کاملTemporal variability of the bioaerosol background at a subway station: concentration level, size distribution, and diversity of airborne bacteria.
Naturally occurring bioaerosol environments may present a challenge to biological detection-identification-monitoring (BIODIM) systems aiming at rapid and reliable warning of bioterrorism incidents. One way to improve the operational performance of BIODIM systems is to increase our understanding of relevant bioaerosol backgrounds. Subway stations are enclosed public environments which may be re...
متن کاملIndoor Air Quality in the Metro System in North Taiwan
Indoor air pollution is an increasing health concern, especially in enclosed environments such as underground subway stations because of increased global usage by urban populations. This study measured the indoor air quality of underground platforms at 10 metro stations of the Taipei Rapid Transit system (TRTS) in Taiwan, including humidity, temperature, carbon monoxide (CO), carbon dioxide (CO...
متن کاملAsbestos exposure among Seoul metropolitan subway workers during renovation of subway air-conditioning systems.
Air quality in underground spaces has seldom been evaluated in Korea. Accordingly, the current study recently evaluated asbestos exposure among Seoul metropolitan subway workers during the renovation of the subway's air-conditioning system. To identify possible routes of asbestos exposure, suspected sources, including gaskets, ceiling boards, ceiling materials, and dust settled inside ducts, we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Industrial health
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2011