Curved crystal x-ray optics for monochromatic imaging with a clinical source.
نویسندگان
چکیده
Monochromatic x-ray imaging has been shown to increase contrast and reduce dose relative to conventional broadband imaging. However, clinical sources with very narrow energy bandwidth tend to have limited intensity and field of view. In this study, focused fan beam monochromatic radiation was obtained using doubly curved monochromator crystals. While these optics have been in use for microanalysis at synchrotron facilities for some time, this work is the first investigation of the potential application of curved crystal optics to clinical sources for medical imaging. The optics could be used with a variety of clinical sources for monochromatic slot scan imaging. The intensity was assessed and the resolution of the focused beam was measured using a knife-edge technique. A simulation model was developed and comparisons to the measured resolution were performed to verify the accuracy of the simulation to predict resolution for different conventional sources. A simple geometrical calculation was also developed. The measured, simulated, and calculated resolutions agreed well. Adequate resolution and intensity for mammography were predicted for appropriate source/optic combinations.
منابع مشابه
Quality assessment system for curved crystal X-ray optics
Doubly curved crystal X-ray optics provide intense focused monochromatic beams from laboratory X-ray tube sources. These optics are employed in crystallography and X-ray fluorescence systems and may find application to imaging. It is increasingly important to understand how optic defects impact performance for these systems. A simulation model was developed to assess the effects of misalignment...
متن کاملBeam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.
Monochromatic imaging can provide better contrast and resolution than conventional broadband radiography. In broadband systems, low energy photons do not contribute to the image, but are merely absorbed, while high energy photons produce scattering that degrades the image. By tuning to the optimal energy, one can eliminate undesirable lower and higher energies. Monochromatization is achieved by...
متن کاملX-ray optics for better diagnostic imaging.
Polycapillary x-ray optics provide an innovative new way to control x-ray beams. Placing these optics after the object to be imaged provides very efficient rejection of Compton scatter, while allowing image magnification without loss of resolution, image demagnification, or image shaping to match with digital detectors. Measured scatter rejection optics had primary transmissions greater than 50...
متن کاملA 15 Mev Linear Electron Accelerator Based Source of Tunable Monochromatic X-rays
In an increasing range of research fields there is a strong demand of high-intensity tunable monochromatic X-ray sources. A promising new approach for the production of tunable high-intensity monochromatic beams in the hard X-ray region is the use of electron accelerators of moderate energy (10 MeV range). We developed at the 15 MeV linear electron accelerator of the Ghent University a monochro...
متن کاملPhase Imaging with an X-ray Talbot Interferometer
X-ray Talbot interferometry (XTI) is described as a novel phase-sensitive X-ray imaging method. XTI uses two transmission gratings, and therefore in principle it functions with cone-beam X-rays of a broad energy band width, allowing its instrumentation with a compact X-ray source. Because an amplitude transmission grating is needed, X-ray lithography and electrochemical gold plating were employ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2009