Gaussian power with cylinder vector field representation for corneal topography maps.
نویسندگان
چکیده
The corneal maps displayed on commercially available corneal topography instruments are really one-dimensional, defining quantities only along a meridian, and ignoring shape information along any other direction. Both axial and instantaneous power have the drawbacks that there is a singularity at the center data point on the videokeratograph axis, and the computed powers and appearance of the corneal map change depending on the videokeratograph axis or on the location of asymmetries. We propose a new representation for corneal topography maps, Gaussian power with cylinder vector field, that has no singularity, and faithfully produces power values and corneal map patterns that are independent of videokeratograph axis or location of asymmetries.
منابع مشابه
Estimating variability in placido-based topographic systems.
PURPOSE To describe a new software tool for the detailed presentation of corneal topography measurements variability by means of color-coded maps. METHODS Software was developed in Visual Basic to analyze and process a series of 10 consecutive measurements obtained by a topographic system on calibration spheres, and individuals with emmetropic, low, high, and irregular astigmatic corneas. Cor...
متن کاملبررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه
ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...
متن کاملThe accuracy of 'power' maps to display curvature data in corneal topography systems.
PURPOSE To quantify the error introduced by videokeratographic corneal topography devices in using a paraxial formula to calculate power over the entire corneal surface, including areas removed from the central paraxial region where the formula is known to be invalid. METHODS Corneal refractive power and two paraxial power approximations were computed as a function of distance from the apex f...
متن کاملCLINICAL SCIENCE Effects of lamellar keratotomy on postkeratoplasty astigmatism
Aim: To determine the changes in postkeratoplasty astigmatism induced by lamellar keratotomy. Methods: A prospective, non-randomised comparative trial of patients undergoing a hinged lamellar corneal flap for treatment of significant astigmatism after penetrating keratoplasty. Uncorrected visual acuity, best corrected visual acuity, refraction, and corneal topography were assessed at 1 and 3 mo...
متن کاملNew method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder.
PURPOSE To derive a method of quantifying corneal topographic astigmatism (CorT) that accurately represents manifest refractive cylinder. SETTING Private practice, Melbourne, Australia. DESIGN Retrospective study. METHOD Axial power measurements obtained using topography in right eyes and left eyes were analyzed. For each Placido ring, an astigmatism value was calculated. The ring astigma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 74 11 شماره
صفحات -
تاریخ انتشار 1997