Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy.
نویسندگان
چکیده
Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 (Xitron Technologies, San Diego, CA). Fifty able-bodied American men (17 to 72 years) and 50 able-bodied American women (17 to 76 years) volunteered as experimental subjects. Xitron continuous global and leg-segmental ECF/ICF procedures for testing were followed for assessing subjects in both the standing erect and lying supine postures. A two-facet, person-by-trial, completely crossed design was used, and all facets were treated as random. Data were independently analyzed for each method, each body posture and each sex group. The major findings of this study were: (1) the leg-segmental method was superior in producing the higher G-coefficients when compared to the global method regardless of gender or posture; (2) the global method resulted in higher G-coefficients in males compared to females regardless of posture; (3) when the global method was used, the relative and absolute error variances were higher for females while the opposite trend was observed when the segmental method was used and (4) when using the global method, the precision of the ECF/ICF ratio scores in females could be increased by simply using the mean of several trials (e.g., by using the mean of 5, 10 or more test trials).
منابع مشابه
Normal Values for Segmental Bioimpedance Spectroscopy in Pediatric Patients
INTRODUCTION Localized limb edema is a clinically relevant sign in diseases such as post-thrombotic syndrome and lymphedema. Quantitative evaluation of localized edema in children is mainly done by measuring the absolute difference in limb circumference, which includes fat and fat-free mass. Bioimpedance spectroscopy (BIS) provides information on the fluid volume of a body segment. Our objectiv...
متن کاملBlood Characterization from Pulsatile Bioimpedance Spectroscopy
The bioimpedance measurements in humans have been receiving considerable attentions during the past two decades because of several advantages, such as low cost, easy application, non-invasiveness and on-line monitoring. The original bioimpedance technique was bioelectrical impedance analysis (BIA). Within a decade, this technique evolved into the more advanced technique known as bioelectrical i...
متن کاملThe correlation between extracellular resistance by electrical biopsy and the ratio of optical low staining area in irradiated intestinal tissues of rats
BACKGROUND Electrical biopsy illustrates a tissue's electrical properties by electrical impedance spectroscopy. However, electrical biopsy parameters are different from conventional morphological-based examinations. The correlation between electrical biopsy and the morphological observation has not been checked. Considering the tissue responses to injury, extracellular resistance should be most...
متن کاملBioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates.
The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop...
متن کاملAssociation between muscle hydration measures acquired using bioelectrical impedance spectroscopy and magnetic resonance imaging in healthy and hemodialysis population
Establishing the effect of fluctuating extracellular fluid (ECF) volume on muscle strength in people with end-stage renal disease (ESRD) on hemodialysis (HD) is essential, as inadequate hydration of the skeletal muscles impacts its strength and endurance. Bioelectrical impedance spectroscopy (BIS) has been a widely used method for estimating ECF volume of a limb or calf segment. Magnetic resona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 27 4 شماره
صفحات -
تاریخ انتشار 2006