Frictional resistance of orthodontic wires tied with 3 types of elastomeric ligatures.

نویسندگان

  • Amanda Carneiro da Cunha
  • Mariana Marquezan
  • Amanda Osório Ayres Freitas
  • Lincoln Issamu Nojima
چکیده

The aims of this study were to determine and compare frictional resistance obtained by low-friction and conventional elastomeric ligatures in the presence of artificial saliva, and observe whether this variable changed after 21 days. Super Slick® low-friction elastomeric ligatures and conventional ligatures of the brands TP conventional® and Unitek® were placed on standard edgewise maxillary central incisor metal brackets, slot .022" × .028" tying rectangular orthodontic wires .018" × .025". Three experimental groups were arranged according to the type of ligature and a control group in which no wires were used. The friction values obtained between the bracket/wire/ligature set were measured using a Universal Test Machine at a speed of 20 mm/minute, at two experimental time intervals: T0 - immediately after specimen fabrication; and T1 - 21 days after fabrication and immersion in artificial saliva at 37 ºC. Conventional Unitek ligatures and the low-friction ligature (Super Slick) showed the lowest friction values at T0. After 21 days (T1), however, conventional Unitek ligatures presented the lowest value. All groups assessed from T0 to T1 showed a numerical reduction in friction values, suggesting that time, heat and humidity may cause elastic degradation, however this was not verified statistically (P > 0.05).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frictional Properties of Self-Ligating Brackets and Low-Friction Ligatures

Problem statement: To evaluate the frictional forces generated by five different orthodontic brackets when used in combination with stainless steel and NiTi archwires in dry conditions at physiological temperature. Approach: Five different types of maxillary canine brackets (Damon 3 MX, Step, Quick, Sprint, Mini Mono) with a slot size 0.022 inch were coupled with 0.016” and 0.019”×0.025” stainl...

متن کامل

A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures.

The aim of this in vitro study was to investigate the frictional characteristics of two types of self-ligating brackets ('A' Company Damon SL and Adenta Time brackets) and two types of pre-adjusted edgewise brackets (TP Tip-Edge and 'A' Company Standard Twin brackets). The test brackets were glued to steel bars and aligned using a preformed jig. Five combinations of archwire size and material w...

متن کامل

Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires

OBJECTIVE To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a 0.10-in ligating wire was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were ...

متن کامل

Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study

BACKGROUND Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conven...

متن کامل

Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2011