A Comparative Evaluation of Accuracy of the Root Zx Electronic Apex Locator in the Presence of Different Irrigants
نویسنده
چکیده
Objective: The aim of this study is to evaluate the accuracy of Root ZX in determining working length in presence of 2% chlorhexidine and 5% sodium hypochlorite. Material and Methods: Thirty extracted, single rooted, single canal human teeth were used. Teeth were decoronated at CEJ and actual canal length determined. Then working length measurements were obtained with Root ZX in presence of 2% chlorhexidine and 5% NaOCl. The working length obtained with Root ZX were compared with actual canal length and subjected to statistical analysis. Results: No statistical significant difference was found between actual canal length and Root ZX measurements in presence of 2% chlorhexidine. Highly statistical difference was found between actual canal length and Root ZX measurements in presence of 5% of NaOCl, however all the measurements were within the clinically acceptable range of ±0.5mm. Conclusion: The accuracy of EL measurement of Root ZX within±0.5 mm of AL was consistently high in the presence of 2% chlorhexidine and 5% sodium hypochlorite. Clinical significance: This study signifies the efficacy of ROOT ZX (Third generation apex locator) as a dependable aid in endodontic working length.
منابع مشابه
The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...
متن کاملارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول کانال دندانهای شیری در شرایط In vivo
Background and Aim: Radiography is the most commonly used technique in root canal length determination, but its application in pedodontics is difficult due to many problems such as radiation hazards, superimposition of permanent teeth buds and uncooperative children. The aim of this study was to investigate the accuracy of an electronic apex locator (Dentaport ZX) in measuring the root canal le...
متن کاملAn Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants
BACKGROUND Cleaning and shaping of root canal system requires various irrigating solutions. The question is whether the presence of irrigation solution alters working length determination using apex locators. The purpose of this study was to compare the accuracy of Root ZX and i-Root apex locator for determining working length in the presence of different irrigating solution. MATERIALS AND ME...
متن کاملComparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملAccuracy of electronic apex locator in enlarged root canals with different root canal irrigants: an in vitro study.
AIM To evaluate the accuracy of Root ZX-II (J Morita Corp) apex locator in enlarged root canals with different root canal irrigants. MATERIALS AND METHODS 48 freshly extracted single rooted mandibular premolar teeth were used. The apical enlargement was done up to #45 K-file as the master apical file (MAF). The teeth were randomly divided into 4 groups and mounted in an experimental apparatus...
متن کامل