Simultaneous estimation of arterial and venous oxygen saturation using a camera
نویسندگان
چکیده
Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.
منابع مشابه
Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملProof of concept non-invasive estimation of peripheral venous oxygen saturation
BACKGROUND Pulse oximeters continuously monitor arterial oxygen saturation. Continuous monitoring of venous oxygen saturation (SvO2) would enable real-time assessment of tissue oxygen extraction (O2E) and perfusion changes leading to improved diagnosis of clinical conditions, such as sepsis. METHODS This study presents the proof of concept of a novel pulse oximeter method that utilises the co...
متن کاملEnd-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning
Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...
متن کاملThe Effect of Controlled Breathing Exercises on Anxiety and Arterial Oxygen Saturation in Chronic Obstructive Pulmonary Disease
Introduction: Anxiety is one of the common symptoms and complications in patients with chronic obstructive pulmonary disease that increases readmission and decreases the quality of life in these patients. Objective: This study aimed to determine the effect of controlled breathing exercises on Anxiety and Arterial Oxygen Saturation in chronic obstructive pulmonary disease in the intensive care u...
متن کاملEffect of Different Positions on Arterial Oxygen Saturation during Enteral Feeding of Preterm Infants Admitted to Neonatal Intensive Care Units
Background: This study aimed to determine the effects of various positions on the arterial oxygen saturation during enteral feeding of preterm infants admitted to Neonatal Intensive Care Units (NICUs). It is assumed that different body positions influence arterial oxygen saturation during enteral feeding.Methods: This crossover clinical trial included 88 infants. The inclusion criteria we...
متن کامل