Correlation of End-Tidal Carbon Dioxide with Arterial Carbon Dioxide in Mechanically Ventilated Patients

نویسندگان

  • Ebrahim Razi
  • Gholam Abbass Moosavi
  • Keivan Omidi
  • Ashkan Khakpour Saebi
  • Armin Razi
چکیده

BACKGROUND Patients undergone mechanical ventilation need rapid and reliable evaluation of their respiratory status. Monitoring of End-tidal carbon dioxide (ETCO2) as a surrogate, noninvasive measurement of arterial carbon dioxide (PaCO2) is one of the methods used for this purpose in intubated patients. OBJECTIVES The aim of the present trial was to study the relationship between end-tidal CO2 tensions with PaCO2 measurements in mechanically ventilated patients. MATERIALS AND METHODS End-tidal carbon dioxide levels were recorded at the time of arterial blood gas sampling. Patients who were undergoing one of the mechanical ventilation methods such as: synchronized mandatory mechanical ventilation (SIMV), continuous positive airway pressure (CPAP) and T-Tube were enrolled in this study. The difference between ETCO2 and PaCO2 was tested with a paired t-test. The correlation of end-tidal carbon dioxide to (ETCO2) CO2 was obtained in all patients. RESULTS A total of 219 arterial blood gases were obtained from 87 patients (mean age, 71.7 ± 15.1 years). Statistical analysis demonstrated a good correlation between the mean of ETCO2 and PaCO2 in each of the modes of SIMV, CPAP and T-Tube; SIMV (42.5 ± 17.3 and 45.8 ± 17.1; r = 0.893, P < 0.0001), CPAP (37 ± 9.7 and 39.4 ± 10.1; r = 0.841, P < 0.0001) and T-Tube (36.1 ± 9.9 and 39.4 ± 11; r = 0.923, P < 0.0001), respectively. CONCLUSIONS End-tidal CO2 measurement provides an accurate estimation of PaCO2 in mechanically ventilated patients. Its use may reduce the need for invasive monitoring and/or repeated arterial blood gas analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital

Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

Should Every Mechanically Ventilated Patient Be Monitored With Capnography From Intubation to Extubation?

Introduction Pro: Every Mechanically Ventilated Patient Should Be Monitored With Capnography From Intubation to Extubation Endotracheal Intubation Preventing Mishaps Operating Room Setting Physiology of the Arterial-Versus-End-Tidal CO2 Difference Carbon Dioxide Elimination Management of Positive End-Expiratory Pressure Alveolar V̇E Minimizing the Duration of Mechanical Ventilation Acute Respira...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2012