Tricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.

نویسندگان

  • Kenji Iino
  • Lucian Lozonschi
  • Anja Metzner
  • Martin Marczynski-Bühlow
  • Jochen Renner
  • Jochen Cremer
  • Georg Lutter
چکیده

OBJECTIVE Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. METHODS A newly designed nitinol stent with SAP was specially designed for the tricuspid annulus. This device was composed of right atrial anchoring elements, a left ventricular tubular stent, and a trileaflet bovine pericardial valve. The stent was coated with a waterproof material, and a pouch containing SAP for minimizing paravalvular leakage was placed beneath the atrial element. Seven pigs underwent minimally invasive off-pump tricuspid valved stent implantation. This was performed through a lower ministernotomy using a transventricular approach under transesophageal echocardiographic guidance. After 1 and 6h, a complete echocardiographic evaluation and hemodynamics (Swan-Ganz catheter) were performed. RESULTS Six of seven pigs exhibited normal hemodynamics immediately after tricuspid valved stent implantation and maintained stability for the entire period of monitoring. In one pig, a part of the atrial stent elements was deployed into the right ventricle, leading to significant paravalvular leakage, and died very soon. All subsequent animals survived with good results in the observation period. Accurate positioning of the valved stent was documented in six of seven pigs. SAP expanded and filled the gap between the stent and the native annulus in all animals. Mild paravalvular leakage was found in two of the six animals. Nevertheless, the observed leakage decreased to trace levels 6h after implantation. In the additional four pigs, only trace tricuspid regurgitation was revealed. No right ventricular outflow tract obstruction was detected. CONCLUSIONS Trans-apical off-pump tricuspid valved stent implantation is feasible in an acute experimental setting, and SAP may help to reduce paravalvular leakages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

Off-bypass implantation of a self-expandable valved stent between inferior vena cava and right atrium.

A glutaraldehyde preserved valved bovine jugular xenograft mounted in a nitinol 'Z' stent, expandable from 7 to 28 mm of internal diameter, was evaluated in vitro (column of water developing a pressure of 45 mmHg and a mock loop including a pulsatile pump) and in vivo in five adult pigs with intra-vascular ultrasound to measure the inferior vena cava diameter via a retroperitoneal access. Throu...

متن کامل

Off-pump tricuspid valved stent implantation: the next step.

OBJECTIVES Off-pump transcatheter valved stent implantation could be a treatment option for patients suffering from symptomatic tricuspid regurgitation (TR) who are classified as inoperable. In this study, we present our recent short-term results of transventricular tricuspid valved stent implantation and compare different stent types for atrial anchorage. METHODS Fifteen pigs received a self...

متن کامل

Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

BACKGROUND Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. METHODS We made a nitinol-wire-based, self-expandable valved stent with leaflets made fr...

متن کامل

Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults.

OBJECTIVES This study was designed to study the behavior of a stent deployed inside human stenotic aortic valves. BACKGROUND Endovascular valved stent (VS) implantation is a promising new therapy for patients with severe calcific aortic stenosis (AS). The precise characteristics of stent deployment in humans have been poorly studied so far. METHODS Thirty-five patients with severe AS were i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2011