Design and fabrication of a multi-purpose soft x-ray array diagnostic system for KSTAR.

نویسندگان

  • Seung Hun Lee
  • Kil Byoung Chai
  • Siwon Jang
  • Won-Ha Ko
  • Junghee Kim
  • Dongcheol Seo
  • Jongha Lee
  • I N Bogatu
  • Jin-Soo Kim
  • Wonho Choe
چکیده

A multi-purpose soft x-ray array diagnostic system was developed for measuring two-dimensional x-ray emissivity profile, electron temperature, Ar impurity transport, and total radiation power. A remotely controlled filter wheel was designed with three different choices of filters. The electron temperature profile can be determined from the ratio of two channels having different thickness of Be layer, and the Ar impurity concentration transport can be determined from a pair of Ar Ross filters (CaF(2) and NaCl thin films). Without any filters, this diagnostic system can also be used as a bolometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Installation of soft X-ray array diagnostics and its application to tomography reconstruction using synthetic KSTAR X-ray images.

Four-array system of soft X-ray diagnostics was installed on KSTAR tokamak. Each array has 32 viewing chords of two photo-diode array detectors with spatial resolution of 2 cm. To estimate signals from the soft X-ray radiation power, typical ne, Te, and argon impurity line radiation profiles in KSTAR are chosen. The photo-diodes were absolutely calibrated as a function of the incident photon en...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Fabrication of polymeric microneedle arrays containing Amphotericin-B for transdermal drug delivery

Background and Aim: Drug delivery through the microneedle array has been considered as an easy and non-invasive method in recent years. The purpose of this study was to design and construct an array of biodegradable polymeric microneedles containing Amphotericin-B to introduce this system and its use in the treatment of cutaneous lesions caused by Leishmania major parasite inoculation as a mode...

متن کامل

Development of a particle injection system for impurity transport study in KSTAR.

A solid particle injection system is developed for KSTAR. The system has a compact size, compatibility with a strong magnetic field and high vacuum environment, and the capability to inject a small amount of solid particles with a narrow injection angle. The target flight-distance of 10 cm has been achieved with a particle loss rate of less than 10%. Solid impurity particles such as tungsten an...

متن کامل

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 2012