Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

نویسندگان

  • Oriel Spierer
  • Michael Waisbourd
  • Yitzhak Golan
  • Hadas Newman
  • Rony Rachmiel
چکیده

BACKGROUND To protect from erosion of the tube in glaucoma drainage device (GDD), the tube is covered by a biologic tissue which is roofed by the conjunctiva. Sclera, pericardium, dura mater and cornea are available as a patch graft. Drawbacks of some of these materials may include high cost and poor appearance. The purpose of this study is to report the long-term outcomes of partial thickness corneal grafts to cover the tube and prevent its exposure, in GDD surgeries. METHODS This was a retrospective review of all patients who underwent Ahmed glaucoma valve implantation and had a minimum follow-up of 12 months. The tube was covered by a 300-micron partial thickness corneal graft taken either from a previous Descemet stripping endothelial keratoplasty procedure or cut from a whole corneal graft button unsuitable for keratoplasty. RESULTS Forty-four patients (45 eyes, mean follow-up of 27.6 ± 11.4 months) were enrolled. The partial thickness corneal grafts maintained clarity throughout follow-up with satisfactory cosmetic results. Mild conjunctival retraction occurred in 4 eyes (8.9%) between 1 and 12 months after the surgery. Corneal graft melting occurred in 3 (6.7%) eyes. Tube exposure and additional surgery to re-patch or suture the conjunctiva over the tube was needed in 1 (2.2%) eye. None of the patients had graft infection or immunologic rejection. CONCLUSIONS Partial thickness corneal grafts have favorable long-term outcome as a patch for GDD tubes with low rates of tube exposure and other complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the righ...

متن کامل

The use of collagen matrix (Ologen) as a patch graft in glaucoma tube shunt surgery, a retrospective chart review

Purpose: To determine the safety and efficacy of collagen matrix as a patch graft in glaucoma drainage surgery. Collagen matrix grafts may be advantageous because they do not need to be harvested from human donors. Methods: An institutional, retrospective review of 43 patients with at least 12 months follow-up status post-glaucoma drainage implant surgery were evaluated for signs of tube erosio...

متن کامل

Short-Term Outcomes of KeraSys Patch Graft for Glaucoma Drainage Devices: A Case Series

Purpose. Tube-related exposure is a known complication of glaucoma drainage device (GDD) surgery. Our objective is to report the early (approximately 1 year) tube exposure rate of implants covered with a keraSys (IOP Inc., Costa Mesa, CA, USA) tissue reinforcement graft. Patients and Methods. A retrospective, noncomparative, consecutive case series of 42 eyes with GDD implantation with keraSys ...

متن کامل

Patch Grafting Using a Cryopreserved Descemet Stripping Automated Endothelial Keratoplasty Flap for Treating Corneal Perforation

A 73-year-old woman with a corneal perforation of undetermined etiology was treated with corneal patch grafting. A residual partial-thickness corneal button obtained during a previous Descemet stripping automated endothelial keratoplasty (DSAEK) surgery and stored at -80°C in Optisol GS for 3 months was used as a patch graft. Five days postoperatively, the anterior chamber was reformed and the ...

متن کامل

Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery.

PURPOSE Conjunctival erosion in glaucoma drainage device surgery can be prevented by the use of patch grafts to cover the extraocular portion of the tube. Several materials can be used, among them human preserved fascia lata. METHODS The authors present a case of a failed Ahmed glaucoma valve due to encapsulation of the bleb, in which the fascia lata patch placed to cover the tube was removed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC ophthalmology

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016