A Potentiometric Indirect Uric Acid Sensor Based on ZnO Nanoflakes and Immobilized Uricase
نویسندگان
چکیده
In the present work zinc oxide nanoflakes (ZnO-NF) structures with a wall thickness around 50 to 100 nm were synthesized on a gold coated glass substrate using a low temperature hydrothermal method. The enzyme uricase was electrostatically immobilized in conjunction with Nafion membrane on the surface of well oriented ZnO-NFs, resulting in a sensitive, selective, stable and reproducible uric acid sensor. The electrochemical response of the ZnO-NF-based sensor vs. a Ag/AgCl reference electrode was found to be linear over a relatively wide logarithmic concentration range (500 nM to 1.5 mM). In addition, the ZnO-NF structures demonstrate vast surface area that allow high enzyme loading which results provided a higher sensitivity. The proposed ZnO-NF array-based sensor exhibited a high sensitivity of ~66 mV/ decade in test electrolyte solutions of uric acid, with fast response time. The sensor response was unaffected by normal concentrations of common interferents such as ascorbic acid, glucose, and urea.
منابع مشابه
Selective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires
In this study, a potentiometric uric acid biosensor was fabricated by immobilization of uricase onto zinc oxide (ZnO) nanowires. Zinc oxide nanowires with 80-150 nm in diameter and 900 nm to 1.5 μm in lengths were grown on the surface of a gold coated flexible plastic substrate. Uricase was electrostatically immobilized on the surface of well aligned ZnO nanowires resulting in a sensitive, sele...
متن کاملThe Electropolymerization of Conductive Polymer Ppy-PANi on Gold Electrodes for Uric Acid Biosensor
Conducting polymers have emerged as potential candidates for biosensors. Due to their straightforward preparation methods, unique properties, and stability in air, conducting polymers have been applied to energy storage, electrochemical devices, memory devices, biosensors, and electro catalysts. Many research studies have been conducted on the use of conjugated polymers in the construction of c...
متن کاملZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoylo...
متن کاملDetection of serum uric acid using the optical polymeric enzyme biochip system.
An optical polymeric biochip system based on the complementary metal oxide semiconductor (CMOS) photo array sensor and polymeric enzyme biochip for rapidly quantitating uric acid in a one-step procedure was developed. The CMOS sensor was designed with N(+)/P-well structure and manufactured using a standard 0.5 microm CMOS process. The polymeric enzyme biochip was immobilized with uricase-peroxi...
متن کاملImmobilized uricase for automated assay of uric acid in serum
The wide use of bound enzyme coils with hexokinase and glucose-6-phosphate dehydrogenase in automated analysis for serum-glucose assay [1, 2-] demonstrates the potential of open tubular heterogeneous enzyme reactors [3] in clinical analysis. Such reactors have also been prepared with other enzymes I-4, 5] and in this paper the authors describe a continuous-flow method for uric acid assay with i...
متن کامل