Mean amplitude deviation calculated from raw acceleration data: a novel method for classifying the intensity of adolescents' physical activity irrespective of accelerometer brand.

نویسندگان

  • Minna Aittasalo
  • Henri Vähä-Ypyä
  • Tommi Vasankari
  • Pauliina Husu
  • Anne-Mari Jussila
  • Harri Sievänen
چکیده

BACKGROUND Using raw acceleration data to assess the intensity of physical activity enables direct comparisons between studies using different accelerometer brands. Mean amplitude deviation (MAD in mg) calculated from resultant tri-axial raw acceleration signal was recently shown to perform best in classifying the intensity of physical activity in adults irrespective of the accelerometer brand. This study compared MAD values and cut-points between two different accelerometers in adolescents. METHODS Twenty voluntary participants (10 girls and 10 boys) of average age of 14 wore two accelerometers (Actigraph GTX3, Pensacola FL, USA and Hookie AM13, Espoo, Finland) and heart rate monitors (M61, Polar Electro Oy, Kempele, Finland) while completing ten 2-min patterns of typical activities ranging from sedentary behaviour to light, moderate and vigorous-intensity locomotion. Bland-Altman method examined the agreement of MAD values between the accelerometers. Correlation coefficient between individual heart rates and MAD values indicated the validity of pattern-based intensity classification. Generalized ordinal logistic regression determined the intensity-specific MAD cut-points for both accelerometers. RESULTS MAD values varied from 3 mg (lying supine) to 1609 mg (running). Hookie gave higher values than Actigraph in accelerations exceeding 700 mg. The correlation coefficient between MAD values and heart rates was 0.96 for Hookie and 0.97 for Actigraph. Respectively, the MAD cut-points were 29 and 27 (light), 338 and 330 (moderate), and 604 and 558 (vigorous). CONCLUSIONS MAD values and cut-points of Hookie and Actigraph showed excellent agreement. Analysing raw accelerometer data with MAD values may enable the comparison of accelerometer results between different studies also in adolescents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches

OBJECTIVES (1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics. METHOD...

متن کامل

Validation of Cut-Points for Evaluating the Intensity of Physical Activity with Accelerometry-Based Mean Amplitude Deviation (MAD)

PURPOSE Our recent study of three accelerometer brands in various ambulatory activities showed that the mean amplitude deviation (MAD) of the resultant acceleration signal performed best in separating different intensity levels and provided excellent agreement between the three devices. The objective of this study was to derive a regression model that estimates oxygen consumption (VO2) from MAD...

متن کامل

Standing Handball Throwing Velocity Estimation with a Single Wrist-Mounted Inertial Sensor

Background. It is well known that overarm throwing is one of the most performed activities in the handball. Shoulder and glenohumeral injuries incidence are high in handball because of both pass, and shooting activity was executed repeatedly in high angular speed. Objectives. This study set out to investigate the usefulness of inexpensive commercial inertial movement sensors for prediction of ...

متن کامل

Design and fabrication of three axes accelerometer

Technology can provide safety in physical practices and improving the performance of these activities, so manufacturing of equipments for these purposes has been considered widely. The aim of the present paper was design and fabrication of three-axis accelerometer. hree acceleration sensors, three gyroscopes for angular velocity measurement, a microcontroller for converting analog data to ...

متن کامل

Analytical study of seismic durability and its destructive effects on structures and distribution of accelerated seismic durability of Iran

Background and objective: Experience with past earthquakes and numerical analysis confirms that the durability of strong earth motion, significantly can affect the amount of failure of civil engineering systems. However, if the durability is related to a parameter which describes the intensity of the earth's motion, such as maximum velocity or maximum acceleration or spectral acceleration, then...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC sports science, medicine & rehabilitation

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015