Application of Multivariate Modeling for Radiation Injury Assessment: A Proof of Concept
نویسندگان
چکیده
Multivariate radiation injury estimation algorithms were formulated for estimating severe hematopoietic acute radiation syndrome (H-ARS) injury (i.e., response category three or RC3) in a rhesus monkey total-body irradiation (TBI) model. Classical CBC and serum chemistry blood parameters were examined prior to irradiation (d 0) and on d 7, 10, 14, 21, and 25 after irradiation involving 24 nonhuman primates (NHP) (Macaca mulatta) given 6.5-Gy (60)Co Υ-rays (0.4 Gy min(-1)) TBI. A correlation matrix was formulated with the RC3 severity level designated as the "dependent variable" and independent variables down selected based on their radioresponsiveness and relatively low multicollinearity using stepwise-linear regression analyses. Final candidate independent variables included CBC counts (absolute number of neutrophils, lymphocytes, and platelets) in formulating the "CBC" RC3 estimation algorithm. Additionally, the formulation of a diagnostic CBC and serum chemistry "CBC-SCHEM" RC3 algorithm expanded upon the CBC algorithm model with the addition of hematocrit and the serum enzyme levels of aspartate aminotransferase, creatine kinase, and lactate dehydrogenase. Both algorithms estimated RC3 with over 90% predictive power. Only the CBC-SCHEM RC3 algorithm, however, met the critical three assumptions of linear least squares demonstrating slightly greater precision for radiation injury estimation, but with significantly decreased prediction error indicating increased statistical robustness.
منابع مشابه
A Discussion on Concept of Symmetry snd Asymmetry
This paper is concerned about the concept os asymmetry. The different types of asymmetry for univariate and multivariate distributions have introduces been considered as well as some of usual asymmetry criteria. A brief overview of method for adding the capability of modeling asymmetry to a symmetry distribution is also a secondary purpose of this paper.
متن کاملApplication of Neural Space Mapping for Modeling Ballistic Carbon Nanotube Transistors
In this paper, using the neural space mapping (NSM) concept, we present a SPICE-compatible modeling technique to modify the conventional MOSFET equations, to be suitable for ballistic carbon nanotube transistors (CNTTs). We used the NSM concept in order to correct conventional MOSFET equations so that they could be used for carbon nanotube transistors. To demonstrate the accuracy of our mod...
متن کاملMultivariate Frailty Modeling in Joint Analyzing of Recurrent Events with Terminal Event and its Application in Medical Data
Background and Objectives: In many medical situations, people can experience recurrent events with a terminal event. If the terminal event is considered a censor in this type of data, the assumption of independence in the analysis of survival data may be violated. This study was conducted to investigate joint modeling of frequent events and a final event (death) in breast cancer patients using ...
متن کاملInvestigation of the Efficacy of Damp-Proof Montmorillonite Nanoclay for Radon Reduction Strategies in Radon Prone Areas of Ramsar
Background: Ramsar, a northern city in Iran, lies on the coast of the Caspian Sea. This city has areas with some of the highest levels of natural radiation measured to date. The radon concentration in some areas of Ramsar is up to 3700 Bq m–3. On the other hand, due to high level of humidity, damp-proof barriers should be used in construction of new buildings in radon prone areas of this cit...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014