BACKGROUND AND PURPOSE Since the introduction of flat panel detector-equipped C-arms, the use of flat panel detector CT (FPCT) in the neuroradiologic angiography suite has become more frequent. This examination implicates its own specific radiation exposure. We used the CT dose index (CTDI) concept and adapted it to the special FPCT geometry to provide a consistent comparison with multisection head CT (cCT). MATERIALS AND METHODS Exposure data obtained for routine scanning during a period of 1 year were used to assess a specific dose of a total of 217 rotational scans performed in 105 patients. One hundred seventy-two scans were 3D digital subtraction angiography (DSA) scans. There were 45 scans that were performed to achieve high-quality, soft-tissue resolution. Dose measurements in cylindrical polymethylmethacrylate (PMMA) phantoms were used to determine the CTDI value and to compare it with the reference values for cCT. In addition, the dose-area product (DAP) was registered and correlated with the CTDI and corresponding dose-length product (DLP) values. Exposure data and dose values were compared with cCT. RESULTS Mean-weighted CTDI value of 3D-DSA was approximately 9 mGy per scan. High-quality, soft-tissue resolution FPCT scans, comparable with cCT, revealed a mean dose value of 75 mGy (reference value for cCT, CTDI(w) approximately 60 mGy). CONCLUSION The high-speed scans used for 3D-DSA revealed a significantly lower CTDI(w) and DLP compared with clinical CT. The high-quality FPCT protocol resulted in a higher dose and should therefore be limited to acute cases, when patient transfer to a CT scanner is considered to be a disadvantage for patient management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional C-arm cone-beam CT: applications in the interventional suite.

C-arm cone-beam computed tomography (CT) with a flat-panel detector represents the next generation of imaging technology available in the interventional radiology suite and is predicted to be the platform for many of the three-dimensional (3D) roadmapping and navigational tools that will emerge in parallel with its integration. The combination of current and unappreciated capabilities may be th...

متن کامل

A novel technique for the measurement of CBF and CBV with robot-arm-mounted flat panel CT in a large-animal model.

BACKGROUND AND PURPOSE Endovascular therapy is an emerging treatment option in patients with acute ischemic stroke and especially in cases presenting late after symptom onset. Information about remaining viable tissue as measured with perfusion imaging is crucial for proper patient selection. The aim of this study was to investigate whether perfusion imaging with C-arm CT in the angiography sui...

متن کامل

Evaluation of the quality of CT-like images obtained using a commercial flat panel detector system

PURPOSE The development of flat panel detector technology has resulted in renewed interest in the possibility of generating CT-like images from rotational angiographic acquisitions. At least two commercial products now use cone beam reconstruction software in conjunction with flat panel detectors to produce such images. The purpose of the work presented here is to report on image quality obtain...

متن کامل

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector.

We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 2008