Retrospective study of the effectiveness of Intra-Aortic Balloon Occlusion (IABO) for traumatic haemorrhagic shock
نویسندگان
چکیده
INTRODUCTION Intra-aortic balloon occlusion (IABO) is useful for proximal vascular control, by clamping the descending aorta, in traumatic haemorrhagic shock. However, there are limited clinical studies regarding its effectiveness. This study aimed at investigating the effectiveness of IABO for traumatic haemorrhagic shock. METHODS This retrospective, observational study included trauma patients who underwent IABO at the Emergency and Critical Care Center of Nippon Medical School Tama-Nagayama Hospital between January 2009 and March 2013. 14 patients were included to this study who were in shock on arrival (systolic blood pressure [SBP] <90 mmHg or shock index ≥1), underwent IABO for resuscitation and temporary haemostasis, and subsequently underwent haemostatic intervention (operation or transcatheter arterial embolization). Patient characteristics, physiological status, SBP, heart rate (HR), initial fluid and blood transfusion, time course, and total occlusion time were compared before and after IABO as well as between the survived (n = 5) and non-survived (n = 9) groups. RESULTS The majority of patients experienced blunt injuries, with an average injury severity score of 29.5. The liver, pelvis, spleen, and mesenterium represented the majority of injured organs. SBP, but not HR, was significantly higher after IABO than before IABO (123.1 vs. 65.5 mmHg, P = 0.0001). The revised trauma score and probability of survival were significantly different between the survived and non-survived groups (both, P = 0.04). The survived group required significantly less blood transfusion volume than the non-survived group (20 vs. 33.7 red blood cell units, P = 0.04). In addition, the survived group required a significantly shorter total occlusion time than the non-survived group (46.2 vs. 224.1 min, P = 0.002). CONCLUSIONS IABO was used for relatively severe trauma patients. SBP was significantly higher after IABO, but was not related to survival. However, blood transfusion volume and total occlusion time were related to survival; therefore, it is important to reduce or shorten these parameters, i.e., immediate definitive haemostasis. IABO is effective for traumatic haemorrhagic shock; however, it is also important to consider these points and potential complications.
منابع مشابه
Intra-aortic balloon occlusion to salvage patients with life-threatening hemorrhagic shocks from pelvic fractures.
OBJECTIVE The purpose of this study was to describe a blinded intra-aortic balloon occlusion (IABO) procedure in pelvic fractures (PF) for patients with critically uncontrollable hemorrhagic shock (CUHS). METHODS Of 2,064 patients treated for PF, 13 underwent IABO during initial resuscitation to control massive pelvic bleeding leading to CUHS. Our IABO procedure consists of internal aortic oc...
متن کاملErratum to: Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting
BACKGROUND Haemorrhagic shock is a major cause of death in the acute care setting. Since 2009, our emergency department has used intra-aortic balloon occlusion (IABO) catheters for resuscitative endovascular balloon occlusion of the aorta (REBOA). METHODS REBOA procedures were performed by one or two trained acute care physicians in the emergency room (ER) and intensive care unit (ICU). IABO ...
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملIntra-aortic balloon pumping (IABP) at different levels of experimental acute left ventricular failure.
Effectiveness of intra-aortic balloon pumping (IABP) as a circulatory assist device was experimentally evaluated in eight groups of dogs at various stages in the sequence: coronary occlusion-myocardial infarctiobacute left ventricular failure-coronary shock. When instituted during the period of reversibiiity of myocardial ischemic changes produced by coronary ligation, IABP improved collateral ...
متن کاملنتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients
Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: Th...
متن کامل