Effect of Heat‐treatment on Accuracy of Infrared Spectroscopy and Digital and Optical Brix Refractometers for Measuring Immunoglobulin G Concentration in Bovine Colostrum

نویسندگان

  • I Elsohaby
  • J T McClure
  • N Dow
  • G P Keefe
چکیده

BACKGROUND Heat-treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality. OBJECTIVES To determine the impact of heat-treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and assessing colostrum quality before and after heat-treatment. ANIMALS A total of 60 Holstein dairy cows on 8 commercial dairy farms. METHODS A cross-sectional study was designed to determine the effect of heat-treatment at 60°C and 63°C each for 30 and 60 minutes duration on colostral IgG concentration measured by the reference radial immunodiffusion (RID) assay, IR spectroscopy, and digital and optical refractometers. RESULTS Colostrum IgG concentration significantly decreased after heat-treatment at 63°C for 30 or 60 minutes as measured by RID, but the IgG values remained unchanged when measured by IR spectroscopy and refractometers. The lowest correlation coefficient found between IR spectroscopy (r = 0.70) and RID results was in colostrum heat-treated at 63°C for 60 minutes. For digital (r = 0.48) and optical (r = 0.50) refractometers, the lowest correlation coefficient was at 63°C for 30 minutes when compared to RID. The accuracy of the IR spectroscopy, digital and optical Brix refractometers was decreased from 91.7 to 80%, 81.7 to 45%, and 80 to 45%, respectively, when colostrum heat-treated at 63°C for 60 minutes. CONCLUSIONS AND CLINICAL IMPORTANCE Radial immunodiffusion, IR spectroscopy, and Brix refractometers exhibit utility for measuring IgG concentration when colostrum heat-treated at 60°C but does not detect decrease IgG concentrations when heat-treated at 63°C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Digital and Optical Refractometers for Assessing Failure of Transfer of Passive Immunity in Dairy Calves

BACKGROUND Failure of transfer of passive immunity (FTPI) is the underlying predisposing risk factor for most early losses in dairy calves. Refractometers, either optical or digital, can be used to assess FTPI as a part of calf health monitoring program on dairy operations. OBJECTIVES To evaluate the performance of and differences between digital Brix and optical refractometers for assessing ...

متن کامل

Technical note: Use of a digital and an optical Brix refractometer to estimate total solids in milk replacer solutions for calves.

The Brix refractometer is used on dairy farms and calf ranches for colostrum quality (estimation of IgG concentration), estimation of serum IgG concentration in neonatal calves, and nonsalable milk evaluation of total solids for calf nutrition. Another potential use is to estimate the total solids concentrations of milk replacer mixes as an aid in monitoring feeding consistency. The purpose of ...

متن کامل

Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum.

Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Sa...

متن کامل

Influence of Starch Sources in Prepartum Diet on Colostrum Quality and Blood Immunoglobulin Concentration of Calves

The main objective of this study was to evaluate the effect of dietary inclusion of wheat or corn as the main source of starch in prepartum diets on colostrum composition, colostrum IgG1 and IgG2 concentrations, serum IgG1 and IgG2 concentrations of calves and efficiency of IgG1, IgG2 and total Ig absorption. For this purpose, thirty primiparous and twenty multiparous Holstein cows were used in...

متن کامل

Optical and Nano structural properties of Hematite (α-Fe2O3) nanorods in interaction with Bovine Serum Albumin (BSA) Protein Solution

Hematite (α-Fe2O3) nanorods were synthesized by hydrothermal method using Cetyltrimethylammonium bromide (CTAB) as a surfactant agent. To study optical, nanostructural properties, and to control the morphology and shape of nanorods, 0.025 mol L-1, 0.05 mol L-1 and 0.1 mol L-1 concentration of CTAB were used. Moreover, the effect of interaction between bovine serum albumin (BSA) A9418-5G protein...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2018