Functional imaging equivalence and proof of concept for image-guided adaptive radiotherapy with fixed gantry and rotating couch
نویسندگان
چکیده
PURPOSE The purpose of this article is to present the first imaging experiments to demonstrate the functional equivalence between a conventional rotational gantry and a fixed-beam imaging geometry, and the feasibility of an iterative image-reconstruction technique under gravitational deformation. METHODS AND MATERIALS Experiments were performed using an Elekta Axesse with Agility MLC and XVI, a custom-built rotating phantom stage, a Catphan QA phantom, and a porcine heart. For the imaging equivalence, a conventional cone beam computed tomography (CBCT) of the Catphan was acquired, as well as a set of 660 x-ray projections with a static gantry and rotating Catphan. Both datasets were reconstructed with the Feldkamp-Davis-Kress (FDK) algorithm, and the resultant volumetric images were compared using standard metrics. For imaging under gravitational deformation, a conventional CBCT of the Catphan and a set of 660 x-ray projections with a static gantry and rotating Catphan were also acquired with a porcine heart. The conventional CBCT was reconstructed using FDK. The projections that were acquired with the heart rotating were sorted into angular bins and reconstructed with prior image constrained compressed sensing using a deformation-blurred FDK prior. Deformation was quantified with B-spline transformation-based deformable image registration. RESULTS For imaging equivalence, the difference between the two Catphan images was consistent with Poisson noise. For imaging under gravitational deformation, the conventional CBCT porcine heart image (ground truth at 0 degrees) matched the static gantry, rotating heart reconstruction with a mean magnitude of <3 mm and maximum magnitude of <5 mm of the deformation vector field. The mean deformation of the rotating heart was 3.0 to 8.9 mm, up to 16.1 mm maximum deformation. Deformation was mainly observed in the direction of gravity. CONCLUSIONS We have demonstrated imaging equivalence in cone beam CT reconstructions between rigid phantom images acquired with a conventional rotating gantry and with a fixed-gantry and rotating phantom. We have presented a method for image reconstruction under a fixed-beam imaging geometry using a deformable phantom.
منابع مشابه
First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system.
The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the li...
متن کاملAn Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region
Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...
متن کاملTreatment couch positioning uncertainties using an EPID-based method
Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...
متن کاملCommissioning and initial stereotactic ablative radiotherapy experience with Vero
The purpose of this study is to describe the comprehensive commissioning process and initial clinical performance of the Vero linear accelerator, a new radiotherapy device recently installed at UT Southwestern Medical Center specifically developed for delivery of image-guided stereotactic ablative radiotherapy (SABR). The Vero system utilizes a ring gantry to integrate a beam delivery platform ...
متن کاملDetermination of the photon beam attenuation by the BrainLAB imaging couch: angular and field size dependence
Highly attenuating radiation treatment couches are no longer useful in the present era of radiotherapy utilizing IMRT and IGRT. Carbon fibers couch tops with its high tensile strength and low density present a useful alternative. The objective of the current study was to quantify the attenuation of megavoltage photons through a Brainlab imaging couch top and headrest at various angles and field...
متن کامل