The Optics and Alignment of the Divergent Beam Laboratory X-ray Powder Diffractometer and its Calibration Using NIST Standard Reference Materials

نویسندگان

  • James P. Cline
  • Marcus H. Mendenhall
  • David Black
  • Donald Windover
  • Albert Henins
چکیده

The laboratory X-ray powder diffractometer is one of the primary analytical tools in materials science. It is applicable to nearly any crystalline material, and with advanced data analysis methods, it can provide a wealth of information concerning sample character. Data from these machines, however, are beset by a complex aberration function that can be addressed through calibration with the use of NIST Standard Reference Materials (SRMs). Laboratory diffractometers can be set up in a range of optical geometries; considered herein are those of Bragg-Brentano divergent beam configuration using both incident and diffracted beam monochromators. We review the origin of the various aberrations affecting instruments of this geometry and the methods developed at NIST to align these machines in a first principles context. Data analysis methods are considered as being in two distinct categories: those that use empirical methods to parameterize the nature of the data for subsequent analysis, and those that use model functions to link the observation directly to a specific aspect of the experiment. We consider a multifaceted approach to instrument calibration using both the empirical and model based data analysis methods. The particular benefits of the fundamental parameters approach are reviewed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crystal Structure Determinations of Three-layer Aurivillius Ceramics Using a New Parallel Beam X-ray Powder Diffractometer

A new high-resolution parallel beam X-ray powder diffractometer incorporating multilayer Xray optics in the incident and diffracted beams was constructed and used to refine the crystal structures of several three-layer Aurivillius ceramics using the Rietveld method. The intent of this study was to determine the feasibility of parallel beam data in a research environment. These results were comp...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

In Situ Thin Film Crystallization Studies Using High Temperature Grazing Incidence X-ray Diffraction (htgixrd)

We describe the experimental procedure and use of high-temperature X-ray diffraction techniques combined with grazing-incidence optics for in situ crystallization studies on several polycrystalline thin films; this technique is referred to as High-Temperature Grazing Incidence X-Ray Diffraction or (HTGIXRD). Temperature calibration techniques, sample positioning issues, and limitations of this ...

متن کامل

Parallel Beam Powder Diffractometry Using a Laboratory X-Ray Source

We report on the application of a new, non-dispersive double multilayer optical arrangement to prepare a parallel beam from a laboratory x-ray source for standardization of powder diffraction reference materials and the associated high accuracy diffractometer. The beam preparation optic uses a graded-spacing parabolic multilayer to gather radiation from a small focus x-ray source and a subseque...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 120  شماره 

صفحات  -

تاریخ انتشار 2015