Performance characteristics of five automated CA 19-9 assays.
نویسندگان
چکیده
Serum concentrations of cancer antigen (CA) 19-9 can be useful in monitoring response to therapy in pancreatic cancer. The objective of this study was to evaluate 5 automated CA 19-9 assays: ARCHITECT 12000 (Abbott Diagnostics, Abbott Park, IL), ADVIA Centaur (Bayer Diagnostics, Tarrytown, NY), UniCel Dxl 800 (Beckman Coulter, Fullerton, CA), IMMULITE 2000 (Diagnostic Products, Los Angeles, CA), and Elecsys E170 (Roche Diagnostics, Indianapolis, IN). All methods were evaluated for limit of detection, linearity, imprecision, method comparison, and reference intervals. Limit of detection results were all below 2.0 kU/L and met the manufacturers' claims. Linearity had deviation from target values that ranged from 4.5% to 26.7%. All methods showed acceptable imprecision with total coefficients of variation less than 8%. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 1.00 to 2.06 and correlation coefficients of 0.85 to 0.98. Between 97.6% and 99.2% of results from healthy volunteers were less than 35 kU/L. All methods show acceptable analytic performance.
منابع مشابه
Evaluation of the UniCel™ DxI 800 Immunoassay Analyzer in Measuring Five Tumor Markers
PURPOSE Tumor marker concentrations in a given specimen measured by different analyzers vary according to assay methods, epitopes for antibodies used, and reagent specificities. Although great effort in quality assessment has been instituted, discrepancies among results from different analyzers are still present. We evaluated the assay performance of the UniCel™ DxI 800 automated analyzer in me...
متن کاملComparison of an immunoradiometric and an immunoluminometric assay for the evaluation of the tumour associated antigens CA 19-9 and CA 125.
We evaluated the levels of CA 19-9 and CA 125 in the sera of healthy individuals, patients with non-neoplastic diseases known to produce elevated serum concentrations of CA 19-9 and CA 125, and patients with malignant tumours. The serum concentrations determined with an immunoradiometric assay (IRMA) and an immunoluminometric assay (ILMA) were compared. The accuracy was determined (as far as th...
متن کاملValidity of carcinoembryonic antigen and carbohydrate antigen 19-9 measurements in pancreatic cyst fluid with a serum-based immunoassay.
Imaging techniques, cytology, and biochemical analysis [including carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA 19-9) concentrations] of pancreatic cyst fluid obtained by endoscopic ultrasound-guided fineneedle aspiration are used to differentiate pancreatic cyst lesions, particularly those with malignant potential (1, 2 ). American College of Gastroenterology guidelines have...
متن کاملDefinitive Characterization of CA 19-9 in Resectable Pancreatic Cancer Using a Reference Set of Serum and Plasma Specimens
The validation of candidate biomarkers often is hampered by the lack of a reliable means of assessing and comparing performance. We present here a reference set of serum and plasma samples to facilitate the validation of biomarkers for resectable pancreatic cancer. The reference set includes a large cohort of stage I-II pancreatic cancer patients, recruited from 5 different institutions, and re...
متن کاملPreliminary evaluation of clinical utility of CYFRA 21-1, CA 72-4, NSE, CA19-9 and CEA in stomach cancer.
BACKGROUND Although various tumor markers have been utilized in management of stomach cancer (SC), only a few reports have described relevance of examples such as CYFRA 21-1 and neuron-specific enolase (NSE). The purpose of this study was to evaluate the potential diagnostic performance of carcinoembryonic antigen (CEA), CA 19-9, CA72-4, CYFRA 21-1 and NSE in patients with SC. MATERIALS AND M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 127 3 شماره
صفحات -
تاریخ انتشار 2007