BACKGROUND Pneumatic tourniquets are medical devices that occlude blood flow to distal part of extremities and are commonly used in upper limb surgeries to provide a dry, clean and bloodless field. To decrease pressure-related injuries and potential risk of complications subjected to the high inflation pressure of pneumatic tourniquet, minimal inflation pressures are recommended. METHODS A new occlusion pressure mathematical model for the upper limb was established based on the correlation analysis between several possible influencing parameters and the minimal pneumatic tourniquet pressure at which the peripheral pulse disappeared was recorded using a digital plethysmograph. A prototype of an adaptive pneumatic tourniquet which automatically varies the pressure in the tourniquet cuff according to the above prediction model was developed for the upper limb which used the lowest possible inflation pressure to achieve occlusion. The prototype comprises a blood pressure monitoring module, an inflatable tourniquet cuff, and a pressure relief mechanism to maintain an optimal cuff inflation pressure. Simulation experiments were conducted to verify the function and stability of the designed adaptive pneumatic tourniquet and clinical experiments using volunteers were undertaken to evaluate the performance of the prototype design in achieving adequate haemostasis in the upper limb. RESULTS Results demonstrated that the mean arterial occlusion pressure was 152.3 ± 16.7 mmHg, obviously below the 250 to 300 mmHg previously recommended (J Bone Joint Surg Br 68:625-628, 1986 and Arthroscopy 11:307-311, 1995). CONCLUSIONS In conclusion, this adaptive method and apparatus which can provide minimal inflation pressure may be a clinically practical alternative for upper limb surgery performed with pneumatic tourniquets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled hypotension and minimal inflation pressure: a new approach for pneumatic tourniquet application in upper limb surgery.

UNLABELLED Minimal inflation pressures are recommended for limb surgery to eliminate complications attributable to high inflation pressures with the pneumatic tourniquets. We applied controlled hypotension and a minimal inflation pressure (CHAMIP) technique to provide a bloodless surgical field. Thirty-six patients scheduled for upper extremity surgery were randomized equally to receive either ...

متن کامل

The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.

Use of the lowest possible cuff inflation pressure should minimize the pathogenic effects of compression beneath the pneumatic tourniquet. Curved tourniquets (designed to fit conically shaped limbs) and wider tourniquets were associated with significantly lower arterial occlusion pressure (AOP) than standard, straight tourniquets on the arms and legs of 26 normal volunteers. These tourniquets w...

متن کامل

Perineural pressures under the pneumatic tourniquet in the upper extremity.

The literature indicates that tourniquet-induced neurological injuries are relatively common and frequently occur at a subclinical level. In order to evaluate the pressure transmitted to the major peripheral nerves of the arm by an externally applied pneumatic tourniquet, a fully implantable biomedical pressure transducer was placed adjacent the radial, median and ulnar nerves in six cadaver up...

متن کامل

A safe and effective low pressure tourniquet. A prospective evaluation.

An unusually wide pneumatic tourniquet has recently become available; we provide a simple formula for its use with a low but effective inflation pressure. A prospective, randomised and controlled trial in 600 lower limb and 150 upper limb operations is reported. The wide tourniquet (12.5 cm) was as effective at low pressure as was a conventional tourniquet (9 cm) inflated to significantly highe...

متن کامل

A Comparison between Single and Double Tourniquet Technique in Distal Upper Limb Orthopedic Surgeries with Intravenous Regional Anesthesia

Background: Several studies have put an effort to minimize the tourniquet pain and complications after conventionaldouble tourniquet intravenous regional anesthesia (IVRA). We expressed in our hypothesis that an upper arm singlewide tourniquet (ST) may serve a better clinical efficacy rather than the conventional upper arm double tourniquet (DT)in distal upper extremity surgeries.Methods: In th...