Liquid-chromatographic determination of pentobarbital in plasma with use of a resin column and an alkaline mobile phase.

نویسندگان

  • R N Gupta
  • P T Smith
  • F Eng
چکیده

We describe a liquid-chromatographic method involving a new, nonsilica column (XAD-2, Hamilton Co.) for pentobarbital in plasma. Plasma is extracted with chloroform after addition of the internal standard, 5-ethyl-5-p-tolyl-barbituric acid. Acidic drugs are back-extracted into alkali, then chromatographed on the resin-base reversed-phase column. The use of alkaline mobile phase allows enhanced sensitivity and detection of barbiturates at 240 nm. The within-run CV for 10 samples was 1.9%, the between-run CV 1.8%. Ten commonly used barbiturates are separated isocratically in less than 15 min. Other commonly prescribed acidic drugs do not interfere with determination of pentobarbital.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 8  شماره 

صفحات  -

تاریخ انتشار 1982